Laserfiche WebLink
885 Jarvis Drive <br /> Sequoia Morgan Hill, 95037 <br /> (408) 776-9600 a— ) 0 <br /> FAX(408)782labico 6 <br /> Analytical <br /> vnvw sequoialabscpm 0 <br /> a <br /> Secor-Rancho Cordova(ARCO) Project ARCO#595,Stockton,CA MMJ0263 <br /> 3017 Kilgore Rd Suite 100 Project Number 38983 Reported <br /> Rancho Cordova CA,95670 Project Manager RustyLLBenkosky 11/06/03 15 47 <br /> ..--Notes and Definitions- <br /> HT-04 <br /> efinitionsHT-04 This sample was analyzed beyond the EPA recommended holding time The results may still be useful for their intended purpose <br /> 0-09 The result was reported with a possible high bias due to the continuing calibration verification falling outside acceptance cntena <br /> QM-07 The spike recovery was outside control limits for the MS and/or MSD The batch was accepted based on acceptable LCS <br /> recovery <br /> QR-02 The RPD result exceeded the control limits,however,both percent recoveries were acceptable Sample results for the QC batch <br /> were accepted based on percent recoveries and completeness of QC data <br /> DET Analyte DETECTED <br /> ND Analyte NOT DETECTED at or above the reporting limit <br /> NR Not Reported <br /> dry Sample results reported on a dry weight basis <br /> — --RPD-----Relative Percent Difference <br /> Sequoia Analytical-Morgan Hill The results in this report apply to the samples analyzed in accordance with the chain of <br /> custody document Unless otherwise stated results are reported on a wet weight basis <br /> This analytical report must be reproduced in its entirety <br /> 16 of 16 <br />