Laserfiche WebLink
HOUSTON LABORATORY <br /> 8880 INTERCHANGE DRIVE <br /> p HOUSTON,TX 77054 <br /> Quality Control Report (713)660-0909 <br /> Shell Oil Company <br /> INC#NIA <br /> Analysis: Diesel Range Organics WorkOrder: 04061001 <br /> Method: CA-DRO Lab Batch ID: 39065 <br /> Method Blank Samples in Analytical Batch: <br /> RunlD., HP_V_0407018-2305258 Units: mg/Kg Lab Sample_ID_ Client SampielD <br /> Analysis Date: 07/01/2004 16:46 Analyst: AE 04061001-01A B1@2.0-2.5' <br /> Preparation Date: 06/29/2004 13:47 Prep By: DMN Method SW3550B 04061001-02A B1@7.5-8' <br /> 04061001-03A B1@11.5-12' <br /> 04061001-04A 62@2.0-2.5' <br /> Analyte Result Rep Limit 04061001-05A B2@4.0-4.5' <br /> Diesel Range 0 anics NQ 2.0 <br /> Surr.n-Pentacmane 113.5 20-154 04061001-06A B2@7.5-8- <br /> 04061001-07A B2@11.5-12- <br /> 04061001-08A B4@2:0-2.5- <br /> 04061001-09A B4A@5.0-5.5' . <br /> ti <br /> 04061001-10A B5@2.0-2.5' <br /> i 04061001-11A 55@4.0-4.5- <br /> 04061001-12A B6@2.0-2.5- <br /> 04061001-13A B6@7.5-8- <br /> 04061001-14A B7@2.0-2.5- <br /> 04061001-15A B8@2.5-3- <br /> 04061001-16A B9@2.0-2.5' <br /> 04061001-17A B10@2.5-3' <br /> Laboratory Control Sample ILCS) <br /> RunID: HP_V_040701B-2305257 Units: mg/Kg <br /> Analysis Date: 07/0112004 16:06 Analyst: AE <br /> Preparation Date: 06/29/2004 13:47 Prep By: DMN Method SW3550B <br /> Analyte Spike Result Percent Lower Upper <br /> Added Recovery Limit Limit <br /> Diesel Range Organics 83.3 72.7 87.2 50 150 <br /> Matrix S ike M5 1 Matrix SiRike Duplicate MSD <br /> Sample Spiked: 04061001-01 <br /> RunID: HP_V_0407018-2305260 Units: mg/Kg <br /> Analysis Date: 07101/2004 19:38 Analyst: AE <br /> Preparation Date: 06/29/2004 13:47 Prep By: DMN Method SW35508 <br /> Analyte Sample MS MS MS% MSD MSD MSD% RPD RPD Law High <br /> Result Spike Result Recovery Spike Result Recovery Limit Limit Limit <br /> Added Added <br /> Diesel Range Organics 8.47 83.3 42.8 41.2 83.1 46.7 46.0 8.81 50 21 175 <br /> Qualifiers: ND/U-Not Detected at the Reporting Limit MI-Matrix Interference <br /> B-Analyte detected in the associated Method Blank D-Recovery Unreportable due to Dilution <br /> J-Estimated value between MDL and PQL `-Recovery Outside Advisable QC Limits <br /> NIC-Not Calculated-Sample concentration is greater than 4 times the amount of spike added.Control limits do not apply. <br /> The percent recoveries for QC samples are correct as reported.Due to significant figures and 04061001 Page 35 <br /> rounding,the reported RPD may differ from the displayed RPD values but is correct as reported. 719104 3.06:53 PM <br />