Laserfiche WebLink
OAir,TD.aCC5 LTU. <br /> AN ENVIRONMENTAL ANALYTICAL LABORATORY ' <br /> The RPD of duplicate samples Eluent and Effluent Lab Duplicate exceeded acceptance limits for some <br /> target species due to target compound concentrations present at less than 5X the reporting limit. ' <br /> The reported LCS for each daily batch has been derived from more than one analytical file. <br /> Definition of Data Qualifying Flags ' <br /> Seven qualifiers may have been used on the data analysis sheets and indicate as follows: <br /> B- Compound present in laboratory blank greater than reporting limit. ' <br /> J- Estimated value. <br /> E- Exceeds instrument calibration range. <br /> S - Saturated peak. ' <br /> Q - Exceeds quality control limits. <br /> U- Compound analyzed for but not detected above the detection limit <br /> M- Reported value may be biased due to apparent matrix interferences. <br /> File extensions may have been used on the data analysis sheets and indicates ' <br /> as follows: <br /> a-File was requantified <br /> b-File was quantified by a second column and detector <br /> rl-File was requantified for the purpose of reissue <br /> i <br /> i <br /> I <br /> 1 <br /> I <br /> I <br /> 1 <br /> 1 <br /> Page 3 of 9 I <br />