My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007901
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5400
>
2900 - Site Mitigation Program
>
PR0522692
>
ARCHIVED REPORTS_XR0007901
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2020 4:44:27 PM
Creation date
4/2/2020 3:34:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007901
RECORD_ID
PR0522692
PE
2957
FACILITY_ID
FA0015465
FACILITY_NAME
FORMER MONTGOMERY WARDS AUTO SRV CTR
STREET_NUMBER
5400
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10227008
CURRENT_STATUS
01
SITE_LOCATION
5400 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Corrective Action Plan <br /> Montgomery Ward Auto Service Center, Stockton, CA <br />' Table 6) TPH-G ranged in concentration from 72 to 670 ppm and BTEX ranged in <br /> concentration from 0 0095 to 3 ppm Toluene at a concentration,ranging from 0 0052 to <br /> 0 0062 ppm was identified in both borings No other TPH-G or BTEX were identified in <br /> soils obtained from borings MW-3 or MW-4 <br /> 1 No TPH-G or BTEX were detected in any soil sample obtained from borings MW-5 or <br /> MW-6 with the exception of sample number MW-6 @ 49-50 5' which contained toluene at <br />' a concentration of 0 0052 ppm (see EAI, 1995) <br /> PHASE VII INVESTIGATION (1996) <br />' In 1996, EAI drilled and installed four hydropunches (HP-1 through HP-4) and the <br /> constructed ground water monitoring well MW-7 (see Figure 2) The purpose of the Phase <br /> VII investigation was to provide better data on the extent of dissolved hydrocarbons in <br />' ground water <br /> Hydropunch locations HP-1 and HP-2 were installed east of Montgomery Ward wells MW- <br />' 5 and MW-6 (see Figure 2) In EAI's opinion, the benzene concentrations detected in <br /> hydropunch HP-1 (36 2 ppb) and hydropunch HP-2 (3 ppb) are low enough to define the <br /> easterly edge of the dissolved ground water plume <br /> Hydropunches HP-3 and HP-4 and well MW-7 were installed south of well MW-5 (see <br /> Figure 2) See Table 7 for testing results associated with soil samples collected as part of <br /> this investigation No hydrocarbons were detected in the water samples collected from <br /> hydropunches HP-3 and HP-4 nor in the water sample collected from well MW-7 (see <br /> Table 8) Based on these testing results, the extent of hydrocarbons in ground water in a <br /> southerly direction did not extend to hydropunch HP-4 Therefore, the southerly edge of <br /> the dissolved phase ground water plume is between well MW-5 and hydropunch HP-4 <br /> Well MW-7 is the most southerly boundary well <br /> Further assessment west of existing Montgomery Ward well MW-4 was proposed as part <br /> of the Phase VII activities However, due to subterranean obstructions this work could not <br /> be completed Only a low level of benzene (1 3 ppb) was detected in Unocal well MW- <br /> 17, which is located westerly of Montgomery Ward well MW-2 (see Figure 2 and EAI, <br /> 1996) <br /> GROUND WATER TESTING RESULTS <br /> Quarterly ground water sampling has been completed at the Montgomery Ward Site from <br /> March 1993 (the first time ground water samples were collected from the site) to date <br /> Project No 1232 A - 4 <br /> SA&WORD 1L32 AA <br />
The URL can be used to link to this page
Your browser does not support the video tag.