Laserfiche WebLink
1534 <br /> low <br /> MCCampbell Analytical, Inc. :www.mcampbes Road,Pittsburg,CA 94565-1701 <br /> Web:www.mccampbell.com E-mail:mainen mccempbelLwm <br /> "When Ouality Counts" Telephone:877-252-9262 Fax 925-252-9269 <br /> WGR Southwest,Inc. Client Project ID: #704.PRI.05; Date Sampled: 05/14/08 <br /> T EARNER Date Received 05/14/08 <br /> 315 W.Pine Street,Suite 8 <br /> Client Contact: Mazda Herbert Date Extracted 05/14/08 <br /> Lodi,CA 95240 Client P.O.: Date Analyzed 05/17/08-05/20/08 <br /> CAM/CCR 17 Metals* <br /> Lab ID 0805377-017A 0805377-018A Reporting Limit for or-1; <br /> Client lD B-7-1 B-7-5 ND means not detected <br /> above the reporting limit <br /> Matrix S S s W <br /> Extraction Type TOTAL TOTAL mg/xs mg/L <br /> ICP-MS Metals,Concentration* <br /> Ana v ba Method: 6020A Emoscimn Method, SW30506Work Older 0805377 <br /> Dilution Factor 1 1 I I I I I <br /> Antimony NO ND 0.5 NA <br /> Arsenic 7.3 6.9 0.5 NA <br /> Barium 160 110 5.0 NA <br /> Beryllium NO ND 0.5 NA <br /> Cadmium NO NO 0.25 NA <br /> Chromium 44 49 0.5 NA <br /> Cobalt 11 8.0 0.5 NA <br /> Copper 25 30 0.5 NA <br /> Lead 17 7.3 1 0.5 NA <br /> Mercury ND NO 0.05 NA <br /> Molybdenum 0.76 ND 0.5 NA <br /> Nickel 36 35 0.5 NA <br /> Selenium ND NO 0.5 NA <br /> • Silver ND ND 0.5 NA <br /> Thallium ND NO 0.5 NA <br /> Vanadium 62 85 0.5 NA <br /> Zinc 8569 5.0 NA <br /> 110 1 106 <br /> Comments <br /> -water samples are reported in pg/L,product/oil/non-aqueous liquid samples and all TCLP/STLC/DISTLC/SPLP extracts are reported in <br /> mg/L,soil/sludge/solid samples in mg/kg,wipe samples in pg/wipe,filter samples in pg/filter. <br /> p means surrogate diluted out of range;NO means not detected above the reporting limit;N/A means not applicable to this sample or <br /> instrument. <br /> TOTAL=acid digestion. <br /> WET=Waste Extraction Test(STLC). <br /> DI WET=Waste Extraction Test using de-ionized water. <br /> i)aqueous sample containing greater than—1 vol.%sediment;for DISSOLVED metals,this sample has been preserved prior to filtration;for <br /> TOTAL metals,a representative sediment-water mixture was digested;j)reporting limit raised due to insufficient sample amount;J)analyte <br /> detected below quantitation limits;k)reporting limit raised due to matrix interference;m)estimated value due to low/high surrrogate recovery, <br /> caused by matrix interference;n results are reported on a dry weight basis see attached initiative. <br /> • DHS ELAP Certification No 1644 ` Angela Rydelius,Lab Manager <br />