Wi • • 1 , <br /> Table 3. Analytical Results for Groundwater-Volatile Organic Compounds -Chevron Service Station#9-6171, 6633 Pacific Avenue, Stockton,California <br /> continued <br /> E%PT ANATION ANATAMC7AT, LABORATORY <br /> 1,2-DCA= 1,2-Dichloroethane APPL= Agriculture do Priority Pollutants Laboratories,Inc of Fresno,California <br /> 1,l-DCA- 1,l-Dichloroethane SAL= Superior Analytical Laboratory of San Francisco,California <br /> TCE=Trichloroethene GTEL=Groundwater Technology Environmental Laboratories,Inc,of Concord, California <br /> PCE=Tetrachloroethene SEQ= Sequoia Analytical Laboratories of Redwood City,California <br /> B= Benzene Quanterra =Quantetra Environmental Services of West Sacramento,California <br /> T=Toluene <br /> E= Ethylbenzene NOTFS <br /> X =xylenes <br /> VOCs = Volatile Organic Compounds ' Well has been dry since December 15, 1969 sampling event <br /> ppb = Parts per billion 3 Chloroform detected at 14 ppb Other VOCs not detected at detection limits of 0 5 to 10 ppb <br /> ND= Not detected ' Not detected at detection lunula of 0 5 to 10 ppb <br /> Not detected at detection limits of 3 to 20 ppb <br /> ANAL YTIrAr_Mt:runnc ' BTEX concentrations included on Table 2 Other VOC's not detected at detection limits of 5 to 50 ppb <br /> All other VOC's were non-detectable with detections limits ranging from 40 to 200 ppb <br /> VOC =EPA Method 8240/EPA Method 624& 7 All other VOC's were non-detectable with detection limits ranging from 100 to 700 ppb <br /> EPA method 8260 ' All other VOC's were non-detectable with detection limits ranging from 22 to 110 ppb <br /> Volatile Tentatively Identified Compounds not present at estimated detection linuts of 100 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 10 Volatile Tentatively Identified Compounds not present at estimated detection limits of 250 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> " Volatile Tentatively Identified Compounds not present at estimated detection limits of 56 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 12 Split samples were taken by Levine-Fricke and analyzed by Quantetra Environmental Services of West <br /> Sacramento,for EPA Method 8260 <br /> Cie-1,2-Dichlomethene was detected at 16 ppb All other constituents were non-detectable <br /> All other constituents were non-detectable <br /> u Cis-1,2-Dichloroethene was detected at 10 ppb All other constituents were non-detectable <br /> 'r Benzene and toluene were detected at 1 3 and 12 ppb, respectively All other constituents were non- <br /> detectable <br /> Toluene was detected at 2 l ppb All other constituents were non-detectable <br /> Cis-1,2-Dichlomethane was detected at 19 ppb Chloroform, 1,1,1-Trichloroethane,benzene,and toluene <br /> were detected at 1 7,7 6, 16,and 1 1 ppb,respectively <br /> " ChIoroform, 1,1,1-trichloroethane, benzene, and toluene were detected at 3 3, 9 0, 13, and 16 ppb, <br /> respectively <br /> Cts-1,2-dichloroethane and 1,1,1,2-tetrachloroethane were detected at 19 and 1 8 ppb,respectively <br /> 512 tvOC TQM <br /> 2 <br />