VMj 0 0 <br /> Table 3 Analytical Results for Groundwater-Volatile Organic Compounds-Chevron Service Station A9-6171,6633 Pacific Avenue,Stockton,California <br /> (continued) <br /> EXPLANATION ANALYTICAL LABORATORIES <br /> 1,2-DCA = 1,2-Dichloroethane APPL = Agriculture&Priority Pollutants Lsboratonea,Inc of Fresno,California <br /> 1,1-DCA = 1,1-11hehloroethane SAL= Superior Analytical Laboratory of San Francisco,California <br /> TCE - Trichloroethene GTEL = Groundwater Technology Environmental Laboratories,Inc,of Concord, California <br /> PCE =Teirachloroethene SEQ = Sequoia Analytical Laboratories of Redwood City,California <br /> B = Benzene <br /> T =Toluene NOTES <br /> E= Ethylbenzene <br /> X = Xylenes ' Well has been dry since December 15, 1989 sampling event <br /> VOCs = Volatile Organic Compounds 1 Chloroform detected at 14 pph Other VOCs not detected at detection limits of 0 5 to 10 ppb <br /> ppb = Parts per billion 3 Not detected at detection limits of 0 5 to 10 ppb <br /> ND = Not detected 4 Not detected at detection limits of 3 to 20 ppb <br /> BTEX concentrations n ntrations iiicludtd on Table 2 Other VOC's not detected at detection limits of 5 to SO ppb <br /> ANALYTICAL METHODS 6 All other VOC's were non-detectable with detections limits ranging from 40 to 200 ppb <br /> 7 All other VOC's were non-detectable with detection Imuts ranging from 100 to 700 ppb <br /> VOC = EPA Method 8240/EPA Method 624& s All other VOC's were non-detectable with detection limits ranging from 22 to 110 ppb <br /> EPA method 8260 9 Volatile Tentatively Identified Compounds not present at estimated detection limits of 100 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 10 Volatile Tentatively Identified Compounds not present at estimated detection limits of 250 ppb Positive <br /> identification or specification between isomers cannot be made without retention tine standards <br /> 11 Volatile Tentatively Identified Compounds not present at estimated detection limits of 56 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> `= Split samples were taken by Levine-Fricke and analyzed by Quanterra Environmental Services of West <br /> Sacramento, for EPA Method 6260 <br /> 33 Cis-1,2-Dichloroetherie was detected at 16 ppb All other constituents were non-detectable <br /> 14 All other constituents were non-detectable <br /> is Cis-1,2-Dichloroethene was detected at 10 ppb All other constituents were non-detectable <br /> 16 Benzene and toluene were detected at 13 and 12 ppb, respectively All other constituents were non- <br /> detectable <br /> 17 Toluene was detected at 2 1 ppb All other constituents were non-detectable <br /> 5121VOC TQM <br /> 2 <br />