Laserfiche WebLink
• • • <br /> Lancaster <br /> Laboratories <br /> Page 4 of 4 <br /> Quality Control Summary <br /> Client -Name ChevronTexaco Group Number 838417 <br /> Reported 01/31/03 at 01 48 PM <br /> Surrogate Quality Control <br /> MSD 94 97 97 92 <br /> Limits 86-118 80-120 - 88-110 z 86-115 _ - <br /> r - - - <br /> Analysis Name BTEX + Oxygenates by 8260E <br /> Batch number P030271AA <br /> Dibromofluoromethane 1,2-Dichlcroethane-d4 Toluene-de 4-Bromofluorobenzene <br /> 3980788 96 94 93 92 <br /> 3980789 98 96 98 92 <br /> 3980790 96 96 96 91 <br /> 3980791 97 96 99 92 <br /> Blank 97 97 100 93 <br /> LCS 95 97 99 94 <br /> Ms 95 94 100 94 <br /> MSD 97 93 99 94 <br /> Limits 86-118 80-120 88-110 86-115 <br /> *-Outside of specification <br /> (1) The result for one or both determinations was less than five times the LOQ <br /> (2) The background result was more than four times the spike added <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> Lancaster PA 17605-2425 <br /> 717 656 2300 Fax 717-656-2681 771E RPS In/2102 <br />