Laserfiche WebLink
CAMBRIA <br /> purging, it shall be decontaminated before purging each well by using soapy water consisting of <br /> Liqui-rli or Alconox fm followed by one rinse of clean tap water and then two rinses of <br /> distilled water If a submersible pump with non-dedicated discharge tubing is used for <br /> groundwater purging, both the inside and outside of pump and discharge tubing shall be <br /> decontaminated as described above <br /> Sample Handling <br /> Except for samples that will be tested in the field, or that require special handling or preservation, <br /> samples shall be stored in coolers chilled to 4° C for shipment to the analytical laboratory <br /> Samples shall be labeled, placed in protective foam sleeves or bubble wrap as needed, stored on <br /> crushed ice at or below 4° C, and submitted under chain-of-custody {COC} to the laboratory The <br /> laboratory shall be notified of the sample shipment schedule and arrival time Samples shall be <br /> shipped to the laboratory within a time frame to allow for extraction and analysis to be performed <br /> within the standard sample holding times <br /> Sample libels shall be filled alt using indelible ink and must contain the site name, field <br /> identification number, the date, time, and location of sample collection, notation of the type of <br /> sample, identification of preservatives used, remarks, and the signature of the sampler Field <br /> identification must be sufficient to allow easy cross-reference with the field datasheet <br /> All samples submitted to the laboratory shall be accompanied by a COC record to ensure <br /> adequate documentation A copy of the COC shall be retained in the project file Information on <br /> the COC shall consist of the project name and number, project location, sample numbers, <br /> • sampler/recorder's signature, date and time of collection of each sample, sample type, analyses <br /> requested, name of person receiving the sample, and date of receipt of sample <br /> Laboratory-supplied trip blanks shall accompany the samples and be analyzed to check for cross- <br /> contamination, if requested by the project manager <br /> Waste Handling and Disposal <br /> Groundwater extracted during sampling shall be stored onsite in sealed U S DOT H17 55-gallon <br /> drums and shall be labeled with the contents, date of generation, generator identification, and <br /> consultant contact Extracted groundwater may be disposed offsite by a licensed waste handler or <br /> may be treated and discharged via an operating onsite groundwater extraction/treatment system <br /> H\ MGT IR Group lnfdSOPs\Groundwater Monitoring and Sampling SOP 07 2005 doc <br /> Page 2 of 2 <br /> I <br /> i <br />