My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006033
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1022
>
2900 - Site Mitigation Program
>
PR0534875
>
ARCHIVED REPORTS_XR0006033
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2020 2:09:08 PM
Creation date
4/7/2020 1:58:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006033
RECORD_ID
PR0534875
PE
2960
FACILITY_ID
FA0020170
FACILITY_NAME
AAA TRUCK WASH/JIMCO TRUCK PLAZA
STREET_NUMBER
1022
Direction
E
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102004
CURRENT_STATUS
01
SITE_LOCATION
1022 E FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 - <br />' Quarterly Report - Third Quarter 2004 <br /> JIMCO TRUCK PLAZA <br />' 22502 South Highway 99, Ripon, California <br />' 1.0. INTRODUCTION <br /> At the request of Mr Dan Koch of Olympian Oil Company, Advanced GeoEnvironmental, Inc <br />' (AGE)has prepared this quarterly report for the Jlmco Truck Plaza,located at 22502 South Highway <br /> 99,Ripon,California(the site) The scope of work included quarterly ground water monitoring and <br />' preparation of this report The location of the site and the immediately surrounding area are <br /> illustrated on Figure 1 The site structures, boring and monitoring well locations are illustrated on <br /> Figure 2 <br />' This report has been prepared in accordance with guidelines established by the Central Valley <br /> Regional Water Quality Control Board (CVRWQCB) for the subsurface investigation of <br />' underground storage tank (UST) sites Background information, including details of previous site <br /> assessment work, was presented in AGE's report titled Preliminary Investigation and Evaluation <br /> Report (PIER), dated 13 December 1999 <br /> 2.0 PROCEDURES <br /> lie Field work was conducted in accordance with guidelines established by the CVRWQCB for the <br /> investigation of UST sites and the San Joaquin County Environmental Health Department (EHD) <br />' for sampling of ground water monitoring wells <br />' 2 1 WELL MONITORING AND PURGING <br /> On 22 July 2004, a Solinst water level meter was used to measure the depth to ground water from <br />' the well casing tops in wells MW-1 through MW-9 The depths to ground water are summarized in <br /> Table 1 <br />' After water levels were gauged, disposable plastic bailers were used to purge the monitoring wells <br /> of a minimum ofthree casing-water volumes(approximately 0 6 to 15 gallons)of ground water The <br />' purged water temperature,pH, and conductivity were measured at regular purge intervals using an <br /> Oakton Water Analyzer,the field data sheets are included in Appendix A Purged water was stored <br /> on-site in 55-gallon drums <br /> 0 <br /> Advanced GeoEnvironmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.