Laserfiche WebLink
f 30'-4" (FIELD VERIFY) <br /> GRA <br /> REMOVE ENTIRE ROOF STRUCTURE DOWN <br /> Architects & <br /> TO TOP PLATE <br /> Associates, nc.............................................. .................... .................................................................................................. _ <br /> TRASH TRASH ���x�-�;, <br /> BIN 1 SIN IP.O. Box 9082 <br /> r410RY Stockton, CA 95208-'1082 <br /> .........................................................................................................:• ., <br /> . .................. <br /> — .I�� '�- ,, .______________ • ------ Phone (2091609-6801 <br /> : -•'• <br /> REMOVE w/c Email, GRA228T5ogmall,com <br /> 1 ......�.�. ...................... . ........................L. ..... I & G.B'S. `•'• i <br /> .. ... .. ............. :. <br /> .I ni <br /> REMOVE.. Stor. Office Back Architecture ♦ Consulting <br /> LAV. <br /> .I I I I I .I I• ;,• <br /> ..¢� ROOF Kitchen 2 <br /> I I ................ <br /> ACCESS <br /> I I I : I I • ' LADDER <br /> ... .. .�- I: _ <br /> I REMOVE 8001 1 I TEMPORARY WALL I� 3/0 " GEORGE A. <br /> �! ACCESS HATCH I BRACING PER I I REMOVE WALL & < RODRIGUEZ <br /> • cl ! & SAVE FOR 1/4.0, TYP. I I? DOORS AS SHOWN <br /> RE--INSTALL �\\ WHERE SHOWN I No. C22875 <br /> 200A REN.: MAY 31, 2019 Q <br /> I i '> \ I C' SUBPANEL<�� <br /> < Back <br /> I REMOVE PACKAGED \ These drawings are property 1 g p p rty of GRA Architects & Associates, Inc., and <br /> HVAC ROOF-TOP \ tchen ore not to be reproduced, changed, copied, or reused without the <br /> :I UNIT" & SAVE FOR \ \ I <br /> I - W/H <br /> expressed written consent of GRA Architects 8c Associates, Inc. <br /> RE-INSTALL <br /> • ..... ............................... . MAIN GAS General C <br /> SERVICE & <br /> ` � ►I w METERTMW & Associates, Inc. <br /> •. • . \ 3/0 TEM P. <br /> e rV <br /> e � 2 Sangu ne <br /> l ane <br /> :............... .......... S/F DOOR <br /> \\ o Stockton, CA 95205 <br /> ` REMOVE ENTIRE ROOF STRUCTURE DOWN N Phone: (209)943-2881 <br /> EXIST. =' TO TOP PLATE I <br /> : I A <br /> SLOPE <br /> � <br /> ................... <br /> TRANSACTION Project For <br /> • c COUNTER <br /> . . : :........1....�.......................... i <br /> u m <br /> Yum <br /> . ........ <br /> Kitchen502 N. Wilson Way <br /> TEMPORARY WALL I I SeatingREMOVE S/S EXHAUST Stockton, CA 95205 <br /> I HOOD & DUCT & SAVE <br /> BRACING PER Area <br /> • • (209)946-9672REMOVE EXHAUST : : : FOR RE-INSTALL P h o n1/4.o, TYP. FAN ROOF—TOP ...... .. .. . e. <br /> WHERE SHOWN I SYSTEM & SAVE <br /> FOR RE—INSTALL <br /> II <br /> Project <br /> VI I <br /> I ! Roof Reconstruction <br /> ! & Tenant Improvements <br /> .... I I •�:= 0 <br /> .................................... ..r..... <br /> ............ .... .... <br /> .. <br /> ............. ......--::-.......................................:.... . .................... ...:. <br /> ............ ....................................................................... 3/0 TEMP. <br /> S/F DOOR <br /> • <br /> .......... ...... .................................................................................. .... ................................. <br /> . <br /> REMOVE ENTIRE ROOF STRUCTURE DOWN Sheet Contents <br /> TO TOP PLATE <br /> Demolition Floor & <br /> REFERENCE DEMOLITION PLAN <br /> REFERENCE Roof Pians <br /> L <br /> DEMOITION <br /> ROOF <br /> NORTHNORTH <br /> SCALE: 1/4„� = 1'-p.. SCALE 1/4” = 1'-0" <br /> NOTE! LEGEND NOTES <br /> REMOVE DILAPIDATED ROOF STRUCTURE <br /> DRAWING STATUS DATE <br /> & ATTACHED MPE CONSTRUCTION; BRACE EXIST. WALLS, DOORS, CASEWORK, & MISC. NON-STRUCTURAL & 1. COORDINATE W/ OWNER ON THE STORAGE OF !EQUIPMENT & APPLIANCE TO PREPARE FOR <br /> EXTERIOR & INTERIOR WALLS AS SHOWN ............••••••••••••••... ..••• ROOF CONSTRUCTION TO BE REMOVED NEW WORK. <br /> PER 1/A-4.0 PRIOR TO THE REMOVAL <br /> ISSUED 07-12-18 <br /> OF <br /> - - <br /> OF ROOF STRUCTURE 2. REMOVE ALL CEILINGS, LIGHTING, & DUCTS WITHIN THE STRUCTURE. <br /> EXIST. WALLS TO REMAIN - REPAIR ANY EXISTING <br /> DEFICIENCIES 3. PROPERLY CAP EXIST. ELECTRICAL CIRCUITS THAT ARE TO REMAIN OR RE-USED. <br /> NOTE! <br /> PRIOR TO REMOVAL OF ROOF STRUCTURE, <br /> CONFIRM ROOF SHTG. THICKNESS, TYPE, & <br /> NAILING PATTERN FOR RE-INSTALLATION <br /> BUILDING PERMIT NO.: TBD <br /> DRAWN BY: NEO KLAYBO <br /> CHECKED BY: GRA <br /> SCALE: AS NOTED <br /> PROJECT NO.: YYD-21805102 <br /> SHEET: <br /> 0 <br /> A ■ <br />