Laserfiche WebLink
REVISIONS BY <br /> PLUMBING NOTES: <br /> C <br /> Plumbing Fixture S c h e d u } e PLUMBING LEGEND ) <br /> 1 ALL FIXTURES, MATERIALS AND WORKMANSHIP SHALL BE IN STRICT ACCORDANCE <br /> 11 <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE AND STATE OF QR ESS/oti <br /> a� <br /> Mark Make/Model Trim Accessories CW COLD WATER LINEVALVE: CALIFORNIA TITLE 24 HANDICAP REQUIREMENTS & LOCAL ORDINANCES. ��Q�� M. <br /> � <br /> WC-1 KOHLER 1.6 GPE 16-3HOT WATER LINE 77 BALANCING VALVE <br /> /4" HARRIER FREE ELONGATED WATER BENEKE 523 ELONGATED SEAT, 2 OWNER WILL PAY FOR ALL APPLICABLE PERMITS AND INSPECTION FEES A5 WATER SERVICE SANITARY T) `�- <br /> K--3505 CLOSET, SLOAN ROYAL 111, SLOAN RESS-C-1.6, NON LOCKING COVER, SEE i TD TRENCH DRAIN - �5� GAS COCK ) CLEAR TOP OF SERVICE IF PLACED IN THE SAME �ry EXP.6�3oa8 M <br /> PRESSURE RUBBER RING, FOLOR MOUNTED ARCHITECTURAL DWGS FOR ADA REQUIRED BY LOCAL CODES. PROJECTION TRENCH SHALL HAVE A LATERAL <br /> LITE RI �W WAST LINE AC ABOVE CEILING PROVIDE SLEEVE 1/2" CLEARANCE OF 30" MIN. $s \P* <br /> L-1 KOHLER SELF RIMMING COUNTERTOP, DELTA 501 ELCTRONIC RI PER HANDICAP REQT'S. GV GREASY WASTE LINE BG BELOW GRADE 3) OWNER SHALL PAY FOR ALL SEWER CONNECTION CHARGES, WATER METER AND CLEAR AROUND PIPE WATER T9rF OF CA��FO�� <br /> K--2196-4 EYE WFHGM FAUCET W/DEARBORN 76OW-1 GRID DRAIN SHEET METAL COLLAR - <br /> Hv HaRrzraNrA VENT My MIXING VALVE TAP FEES, MAJOR FACILITIES CHARGES AS MAY BE REQUIRED BY LOCAL <br /> PENNWGTON & PVC P-TRAP BRASSCRAFT KTSRI7FC STOPS & FILL OPENING w/slxA FLEX METAL BUILDING ROOF SAFE BY <br /> B-16A SUPPLY HOSES PLUMBEX 2002 P--TRAP & SD— STORM DRAIN LINE WC WATER CLDSET GOVERNING AUTHORITIES. FOR WATERTIGHT SEAL ;r 30" MIN <br /> ANGLE STOP INSULATION METAL BUILDING r''%:; 6515 Cumberland Place. <br /> —C — CONDENSATE DRAIN UR URINAL DR W BAND MANUFACTURER ADHERED TO 12' MIN. <br /> S-1 OWNER 3 COMPARTMENT SINK COMPLETE WITH WASH WAND, SIIDE OF PIPE )>;.-, 2nd Floor, Suite 2. <br /> FURNSIHED HOT AND COLD WATER TAPS, DRAINS, STOPPERS AND V, VR, vTR VENT, VENT RISER, VENT THRU ROOF L LAVATORY 4) ROUGH-IN AND CONNECT TO ALL FIXTURES AND EQUIPMENT REQUIRING GAS, FIIWISHED ROOF - SEE ARCH ' <br /> SIDEBOARDS WATER OR WASTE LINES AS INDICATED ON PLANS. DWGS - FLASHING INSTALLATION SHALL OPEN TRENCH Stockton, CA 95202 <br /> -SS, SSA - WASTE, WATER DROP S SINK 6" MIN. `s •: 9° MIN. Tel: 209. 662 bb23 <br /> AD-1 KARP DSC GRAY PRIMERED ACCESS DOORS - SEE DRAWINGS FOR PAINT TO MATCH RWL RAIN WATER LEASER SS, MS SERVICE SINK, MOP SrNK 1/4"-1/�mm MATCH ROOFING MANUFACTURERS ;;;.;;: SANITARY SEWER <br /> 214M TYPE OF LOCKING MECHANISM. UNLESS OTHERWISE ARCHITECTURAL SURFACES. DETAILS TO MAINTAIN WARRANTY ._. ,, ,_Y, SLOPE NOT MORE THAN email: <br /> 5) INSULATE. HOT WATER LINES AND DRAIN LINES UNDER LAV'S WITH 3/4"THICK <br /> NOTED, FURNISH DOORS WITH SLOTTED 1/4" LOCKS. RD ROOF DRAIN DF DRINKING FOUNTAIN ATTACH SUPPORT TO BLOCKING _ 1 IN 2, PIPE MUST BE lozanofmla mail.com.co <br /> z 1'. i PLACED BELOW THIS LINE �g P <br /> MIN SfZE 15 12x12. AD AREA DRAIN FHS FIRE HOSE STANDPIPE INSULATION PER TITLE 24 REQUIREMENTS. W/J" LAGS FOR WOOD CONCRETE & SLEEVE 2 ` <br /> TP-1 PPP, INC, PROVIDE DU- ACCESSORY WHERE PRIMER IS USED MOUNT IN WALL BEHIND AD-1 8x1-4"SM SCREW FOR STEEL FULL WIDTH FOR CASES OF LESS THAN <br /> PR-500 EOR MORE THAN ONE DRAIN, WITH SOV. CB, DI CATCH BASIN (DROP INLET) INV INVERT ELEVATION 6) PROVIDE CLEANOUT ON ALL WASTE LINES AT UPPER TERMINAL OF EACH RUN OF ----Z-PURLOIN - SEE 3'-0", OTHERWISE USE <br /> PRIME RITE STEPPED FOOTING <br /> CC CLEAN OUT FIN, GD, FINISH GRADE PIPING, LINE TERMINATIONS, CHANGES IN DIRECTION AND AT 10GFT. INTERVALS METAL BUILDING <br /> WCO WALL CLEAN OUT POINT OF CONNECTION 1 CUT OPENING IN ROOF 6" MIN.F NOT LESS <br /> FD-1 ZURN ZN415 TYPE B STRAINER FLOOR DRAIN, 2° OUTLET, TRAP It`-"- (PIER U•P•C•1 / MINIMUM 2" LARGER THAN PIPE THAN 1B" <br /> PRIMER FITTING *_FCO FLOCIR CLEAN OUT AD ACCESS DOOR 8 GA PIAS BRACE / REFER TO STRUCTURAL/ARCG DWGS <br /> WITHIN 24" OF ROOF •. + <br /> WH-1 STATE 3o GALLON GAs FIRED wnTER HEATER, coMPLEr� Yc❑ YARD CLEAN nUr CI CAST IRON 7) LAVATORY AND SINK FAUCETS SHALL BE CERTIFIED BY THE MANUFACTURER WITH DECK 2 REQUIRED IF OPENING IS LARGER THAN 8"0 $ , <br /> G56-30-YB WITH ZINC ANODE, DRAIN VALVE, T&cP RELIEF VALVE THE CALIFORNIA ENERGY COMMISSION/COMPLY WITH TITLE 24 REQUIREMENTS PIPE CLAMP PIPE UP THROUGH PIPE TH U FOOTING <br /> RS AFD FLOOR DRAIN � CENTER LINE ROOF <br /> �—FS FLOOR SINK HDR HEADER FOR MAXIMUM ALLOWABLE FLOW RATES. (3 G.P.M. MAX.) DLTAIL P5 <br /> VENT FLASHING 4 PLUG AT FINISH GRADE <br /> TP TRAP PRIMER DWN DOWN 8) PLUMBING CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES. (IE: DETAIL P 5 OR FLUSH W/ FLOOR w <br /> CW, D, R — COLD WATER CROP) (RISER) MBH THOUSANDS OF BTU PER HOUR <br /> PLUMBING MATERIALS. STRUCTURAL, MECHANICAL, AND ELECTRICAL). <br /> HW,i3,R,RT--- HW SUPPLY (DROP) (RISER) (RETURN) HIPC NOT IN PLUMBING CONTRACT <br /> THW—T — TEMPERED HOT WATER (115' F) HW HAND WASH STATION CONCRETE BOX LABELED SEWER <br /> MATERIALS 9) PLUMBING CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIAL, LABOR, ETC., 'OR' Q <br /> —G, PG — NATURAL GAS LOW PRESSURE (PROPANE) HS HOSE STATION WHETHER SHOWN ON THESE PLANS OR NOT, NECESSARY TO PROVIDE A ZURN 415 BRASS CLEANOUT BOX <br /> COLD AND HOT WATER INSIDE BUILDING -- HPG — HIGH PRESSURE GAS WH WATER HEATER COMPLETE, WORKABLE, AND CODE-APPROVED PLUMBING SYSTEM. JE <br /> IN FINISHED FLOORp <br /> TYPE 'L' COPPER ABOVE GROUND AND TYPE 'K' BEL.❑W, FURNISH SHUT❑FF - CA COMPRESSED AIR iSTOP - SEE FIx CONNECTION SCHEDULEVALVES WHERE SH❑WN, SHUT OFF VALVES SI{ALL BE BALL TYPE WITH 10) GAS MAIN AND METER TO BE BY UTILITY COMPANY (VERIFY LOCATION). PROVIDE HB HOSE BIBB XXXXXX DEMOLITION, TBR NG SWEEP 'L'TEFLON SEATS, STAINLESS STEEL BALL, AND DOUBLE ❑ RING STEM 1/4 GAS SHUT-OFF VALVE CONSPICUOUSLY MARKED. DEGREETURN, VALVES TO BE RATED FOR WTG SERVICE. PR❑VIDE DIELECTRIC © UNDER PLUMBING CONTRACT FSP FIRE SPRINKLER FLUE 1 11-4 <br /> UNIONS AT ALL. DISSIMILAR METAL CONNECTIONS, INSULATE HOT WATER SUV SHUT OFF VALVE COP CUT OFF POINT 11} PROVIDE WATER HEATER WITH PRESSURE, TEMP., RELIEF VALVA AND 314" DRAIN 3/4" HWs 3/4" cw LlNE RT - SEE PLAN h--! 4_, <br /> SUPPLY AND RETURN LINES W/1" FIBERGLASS ASJ MEETING THE FOR SIZES <br /> REQUIREMENTS OF T-24 MANDATORY FEATURES, UNLESS NOTED ON LINE TO THE EXTERIOR OF THE BUILDING WITH THE END OF THE PIPE NOT MORE � SEE PLUMBING FLOOR <br /> DRAWINGS, ALL WATER LINES SHALL BE KEPT OUT OF THE SLAB, THAN TWO (2) FEET NOR LESS THAN SIX (6) INCHES ABOVE THE GROUND AND SOV SOV PLAN FOR SIZE <br /> FIXTURE CONNECTION SCHEDULE POINTING DOWNWARD. 1/2"x3" LAG BOLT TO <br /> COLD AND HOT WATER OUTSIDE BUILDING PLUMBING SANITARY WATER BLOCKING ATTACHED To CLEANOUT TO GRADE 2 <br /> SCH 40 CPUC BELOW GRADE, SIZE AS INDICATED ON THE DRAWINGS. FIXTURE SEWER VENT COLD HOT 12) VERIFY ALL EXISTING CONDITIONS (ON-SITE)AND UTILITY CONDITIONS (OFF-SITE) TRUSSES <br /> CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES PRIOR TO BIDDING AND CONSTRUCTION/NOTIFY ARCHITECT ENGINEER OF ANY <br /> WATER CLOSET FV 3' 2 1 - (ENGINEER) 18 GAX2" WIDE STRAP DETAIL P Q <br /> CONTRACTOR SHALL DISINFECT WATER LINES PER AWA GUIDLINES AND WATER CLOSET FT 3" 2" 112" - DISCREPANCIES AND/OR CONDITIONS OTHER THAN THOSE SHOWN. LOCATE 12" FROM PLUG AT FINISH GRADE <br /> PROVIDE THREE COPIES FRUM AN INDEPENDENT TEST LAB, WATER SHALL OR FLUSH w/ FLOOR <br /> URINAL FV 2" 1-112" 3I4" _ TOP of TANK <br /> BF TESTED FOR WATER BORNE BACTERIUM, SPORIDIUM AND OTHER 13 WHERE WATER AND SEWER PIPES ARE RUN IN THE SAME TRENCH 3/4" TPR LINE <br /> URINAL FT 2" 1-112" 112" - � <br /> PATHOGENS AT THE TIME OF OCCUPANCY AND CERTIFY THE SYSTEM TO FLOOR SINK I_I! <br /> PASSED THESE TESTS, LAV 2" 1-112" 112" 1/2" " 1/2"G TO HEATER 3 1 I! CONCRETE BOX LABELED SEWER <br /> BAR SINK 2" 1-112" 912" 112" a) THE BOTTOM OF THE WATER PIPE AT ALL POINTS SHALL BE AT LEAST 12 ABOVE <br /> W/6" DRIP LEG -- SE <br /> CLASSROOM SINK 2" 1-1/2" 1/2" 112" THE TOP OF THE SEWER. FLOOR PLAN FOR BRASS CLEANOUT Box <br /> SEWER - THE USE OF ABS PIPE AND FITTINGS IS PROHIBITED, ALL PIPE b THE WATER PIPE SHALL BE PLACED ON A SOLID SHELF EXCAVTED AT ONE SIDE OF CONTINUATION IN FINISHED FLOOR <br /> SHALL BE CI PIPE WITH METAL ESCUTCHEONS, N❑ HUB COUPLINGS WITH A KITCHEN SINK 2" 1-112" 112" 1/2" ) <br /> MINIMUM ❑F 2 BANDCLAMPS FOR PIPE 2--1/2" AND SMALLER AND A MINIMUM MOP SINK 3" 2" 3/4" 314" A COMMON TRENCH. <br /> [IF 4 BAND CLAMPS FOR PIPE 3-6 CLEANOUTS SHALL BE PROVIDED TRAP PRIMER - - 112" - <br /> EVERY 100 ET AND AT EACH CHANGE OF DIRECTION GREATER THAT 90L, FD-2" 2" 1-112" - - 14) ALL SINKS MUST BE EQUIPPED WITH HOT AND COLD WATER DISPENSED FROM 22GA GI DRAIN <br /> BUILDING SERVICE IS 6", FD- 3" 3" 2" - - MIXING FAUCETS. PAN W/3/4"DRAIN <br /> - SET ON 4x 12 MIN <br /> FLOOR SINK 2" 2" 1-112" - - BLOCKING �u -D Q <br /> SEE PLUMBING FLOOR <br /> VENT LINES - SEE SEWER LINES, FLOOR SINK 3" 3" 1-112" - - 15) NO VENT PIPE SHALL TERMINATE CLOSER THAN 10 FT. FROM ANY INTAKE AIR. RAIN PLAN FOR SIZE <br /> SHOWER-RES. 2" 1-112" 1/21' 112" BLOCKING TO ALLOW FGR 2 WAY CLEANOUT 3 <br /> HVAC CONDENSATE DRAIN LINES - TYPE 'M' COPPER PIPE AND FITTINGS, EYEWASH 2" 1-112" 1/2" - 16) PROVIDE BACKFLOW PREVENTION DEVICE IF REQUIRED BY CODE OR LOCAL OVERFLOW DRAIN <br /> PR❑VIDE CLEANOUT AT EACH CHANGE OF DIRECTI❑N AND AT COIL GOVERNING AUTHORITY. CONTRACTOR SHALL VERIFY THIS WITH GOVERNING WH - 1 M O U N TI N G. DETAIL P 5 <br /> JURISDICTION AND INCLUDE COST OF SAME IN BID5 <br /> CONNECTION, DETAIL P5 <br /> GAS IN BUILDING <br /> S <br /> 7" WC SERVICE - SCH 40 GALVANIZED IR❑N PIPE AND FITTINGS OUTSIDE IT SHALL BE THE RESPONSIBILITY OF THE 17) ALL VENTS AND PIPING THRU ROOF SHALL BE FLASHED AND COUNTER FLASHED Q <br /> BUILDING ANI] SCH 40 BLACK IRON PIPE INSIDE BUILDING, PAINT WHERE MECHANICAL, PLUMBING, ELECTRICAL_ ANDAS REQUIRED TO MAKE WATERTIGHT. ` <br /> EXPOSED TO INTERIOR FINISHES, GENERAL CONTRACTOR TO EXAMINE THESE 18) ALL FLOOR DRAINS REQUIRE TRAP PRIMERS. W H r <br /> GAS - SITE AND EXTERIOR TO BUILDING DRAWINGS AND CORRESPONDING -PRECISION PLUMBING PRODUCTS MODEL#PR-500 (UNDER LAV.) <br /> MDPL SCH40 GAS PIPE WITH SOCKET WELD FITTINGS UTILIZING A HEAT SPECIFICATION SECTIONS FOR WORK TO BE <br /> FUSION PR❑CESS, PIPE SHALL BE LAID IN 4" BED OF SAND AND COVERED PERFORMED BY OTHER TRADES SHOWN ON 19) PROVIDE THE BETWEEN DOWNSPOUTS AND SITE DRAINAGE. (REFER TO GRADING 0 <br /> WITH 6" SAND PRIG TO BACKFILL, MINIMUM DEPTH OF BURY IN PARKING THESE DRAWINGS. PLAN FOR DOWNSPOUT AND AREA DRAIN LOCATIONS). F�-I <br /> AREAS IS 24" AND IB" IN ALL OTHER PLACES, <br /> 20) HOSE BIBBS SHALL BE PROTECTED BY APPROVE NON-REMOVABLE BACKFLOW N <br /> FIXTURFS PREVENTION DEVICES. <br /> ROUGH IN ALL HANDICAP FIXTURES PER THE DETAILS FOUND IN UBC CHAPTER <br /> 11, THE ARCHITECTURAL DRAWINGS AND LOCAL CODE REQUIREMENTS, N❑TTFY 20) PROVIDE LEAD ROOF JACKS FOR ALL ROOF PENETRATIONS. <br /> ARCHITECT IN WRITING OF CONFLICTS, <br /> SUBMITTALS 20) PROVIDE THRUST BLOCKS PER CODE IF RUBBER GASKETED JOINT FIRE SERVICE <br /> PR❑VIDE SEVEN SETS OF SUBMITTALS FOR REVIEW, PIPING IS PROPOSED. <br /> INSTALLATI❑N 20) PROVIDE STAINLESS STEEL FLEX CONNECTIONS FOR SUPPLY AT WATER <br /> BRACE ALL PIPE AND DUCT SYSTEMS PER SMACNA SEISMIC RESTRAINT CLOSETS./ANGLE STOPS TO BE BRASS. <br /> GUIDELINES INCLUDING CHANGES OF DIRECTION AND CHANGES IN ELEVATION OF <br /> METRE THAN 10', 20) ALL TUBI SHOWER OPENINGS SHALL BE RODENT PROOF WITH 1" CEMENT <br /> COVERING IN AN APPROVED MANNER, <br /> 20) PLUMBING CONTRACTOR TO VERIFIY LOCATION OF WATER CLOSET WASTE WITH <br /> FLOOR JOIST LAYOUT. LOCATE WATER CLOSET TO CAUSE NO INTERFERENCE TO <br /> CONTINUOUS FLOOR JOIST FRAMING. <br /> -REFER TO DETAIL 14/S6 FOR FRAME OUT CONDITION WHERE RELOCATION OF <br /> WATER CLOSET IS NOT POSSIBLE. <br /> 26) ALL PIPING SHALL BE CONCEALED WITHIN BUILDING COMPONENTS, AND SHALL <br /> NOT BE EXPOSED TO PUBLIC VIEW. NOTIFY OWNER AND ARCHITECT WHEN <br /> CONCEALING SUCH CAN NOT BE ACHIEVED. <br /> 26) PROVIDE (MW.) 12"x12" ONE-HOUR RATED ACCESS PANEL (WALL OR CEILING)AS (J <br /> REQUIRED FOR ACCESS TO PLUMBING VALVES, ETC. Q <br /> 26) ALL DOMESTIC WATER VALVES UP TO AND INCLUDING OPEN 2 INCHES IN SIZE W <br /> SHALL BE MADE OF BRASS OR OTHER APPROVED MATERIALS. Q <br /> -EACH GATE VALVE SHALL BE FULL-WAY TYPE WITH WORKING PARTS OF z <br /> NON-CORROSIVE MATERIAL. Q <br /> J <br /> 29) DRAINAGE CONNECTION SHALL NOT BE MADE INTO DRAINAGE PIPING SYSTEM D" <br /> WITHIN EIGHT (8) FEET (VERTICAL AND HORIZONTAL) OF ANY VERTICAL OR Z <br /> HORIZONTAL CHANGE OF DIRECTION OF A STACK CONTAINING SUDS-PRODUCING <br /> FIXTURES. CC) <br /> 29) PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH ON GRADE CONCRETE <br /> J <br /> FLOORS. -SLEEVES SHALL BE SIZED SO THAT THERE IS A MINIMUM OF ONE HALF p_ <br /> (112) INCH CLEARANCE AROUND THE PIPE AND OR INSULATION. <br /> Date 04/2018 <br /> 31) THE BACKFLOW ASSEMBLY AND DEVICE SHALL BE PROTECTED FROM FREEZING BY <br /> A METHOD ACCEPTABLE TO THE LOCAL JURISDICTION. Scale <br /> Drawn <br /> Job <br /> Shoot Number <br /> P■w4 <br /> Of <br />