Laserfiche WebLink
casing are factory machine slotted and will be installed approximately 5 feet above <br /> and 15 feet below first-encountered water level The screened interval will allow <br /> for fluctuation in water level and for monitoring floating product <br /> Upon collection of a suitable water sample, holes will be backfilled with cement <br /> grout containing 5 percent bentonite or concrete will be placed above the bentonite <br /> seal to the ground surface <br /> ' Exploratory boring logs and well construction details will be prepared for the final <br /> written report <br /> ' Well installation will be carned out by a properly licensed contractor A permit for <br /> the wells will be required from San Joaquin County Environmental Health <br /> IDepartment <br /> 1 <br /> ' B B-4 <br /> s <br />