My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORADA
>
4255
>
1600 - Food Program
>
PR0526657
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/9/2021 8:45:42 AM
Creation date
4/8/2020 4:52:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0526657
PE
1619
FACILITY_ID
FA0018047
FACILITY_NAME
RALEYS #306
STREET_NUMBER
4255
STREET_NAME
MORADA
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12429014
CURRENT_STATUS
01
SITE_LOCATION
4255 MORADA LN
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES KEYED NOTES <br /> POLE C.B. SERVICE LOAD KVA SERVICE C.B. POLE POLE C.B. SERVICE LOAD KVA SERVICE C.B. POLE A. CONTRACTOR RESPONSIBLE FOR MAINTAINING 1. EXISTING TWO-SECTION PANELBOARD. ALL LOADS <br /> INTEGRITY OF EXISTING LIGHTING CIRCUITRY ARE EXISTING UNLESS OTHERWISE NOTED. IR <br /> NO. AMP/P TOTAL TYPE A B C TYPE TOTAL AMP/P NO. NO. AMP/P TOTAL TYPE A B C TYPE TOTAL AMP/P NO. AND/OR BMS CONTROL FOR RE-USE WHEREVER <br /> POSSIBLE PER PLANS. ALL CIRCUITS NOT TO BE 2. SEE SECTION 2 OF PANEL FOR TOTAL LOAD <br /> 1 20/1 RECPT 129 MIXER 1.4 A 2.60 A 1.2 20 QT MIXER 110 20/1 2 1 15/1 SPARE 0.18 A 0.2 BAKERY REGISTER 20/1 2 REUSED SHALL BE TERMINATED AT NEAREST CODE SUMMARY ON BOTH SECTIONS. <br /> 3 20/1 RECPT 129A MIXER 1.2 A 2.60 A 1.4 RECPT JAVA CAFE 20/1 4 3 15/1 SPARE 0.50 A 0.5 RECEPT- FISH PREP 20/1 4 COMPLIANT JUNCTION BOX. UNUSED CIRCUITS ARE <br /> TO BE RE-IDENTIFIED AT ORIGINATING PANEL 3. PROVIDE NEW CIRCUIT BREAKER AS SHOWN. AICNOB <br /> 5 20/1 RECPT BAKERY PREP 0.6 A 0.60 SPARE 20/1 6 5 15/1 SPARE SPARE 20/1 6 SCHEDULE AS "SPARE". AND MANUFACTURER SHALL MATCH EXISTING. HILL <br /> 7 20/1 OVEN CONTROLS 122D 1 A 1.00 SPARE 20/1 8 7 15/1 RECEPT SELF SERV 0.2 A 0.98 A 0.8 RECEPT-WAREHOUSE 20/1 8B. REFER TO RALEY'S SCOPE OF WORK 4. CONTRACTOR TO REMOVE ALL DEVICES IN THIS F ® ® D S <br /> VERIFY ALL EXISTING CIRCUITRY <br /> 9 20/1 OVEN CONTROLS 122D 0.2 A 1.60 A 1.4 RECPT WASH RM 20/1 10 9 20/1 SPARE 0.60 D 0.6 BAKERY SCALES 20/1 10 DOCUMENTATION FOR FURTHER INFORMATION. IN THIS AREA. SAFE AREA. TRACE AND OFF CIRCUITRY AND DATA TO <br /> 11 20/1 ESPRESSO GRINDER 310C 1 A 2.00 A 1 RECPT BAKERY STORAGE 20/1 12 11 15/1 RECEPT-SUB SHOP 0.9 A 1.30 D 0.4 DELI SCALES 20/1 12 C. CONTRACTOR RESPONSIBLE FOR MAINTAINING CODE COMPLIANT JUNCTION BOXES ABOVE CEILING <br /> �® <br /> 13 20/1 UADEQUATE LIGHTING IN ALL AREAS OF WORK SPACE IN MEAT PREP AREA. <br /> C REFRIGERATOR 1 A 1.00 SPARE 20/1 14 13 15/1 CAMERA REGISTER 0.2 A 0.38 D 0.2 DELI SCALES 20/1 14 DURING DEMOLITION AND CONSTRUCTION. <br /> 15 20/1 RECPT BAKERY PREP 0.8 A 1.30 A 0.5 RECPT CAFE 20/1 16 15 15/1 CAMERA REGISTER 0.4 A 1.36 A 1.0 RECEPT-TECH ROOM 20/1 16 5. CONTRACTOR TO REMOVE ALL EXISTING <br /> D. CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO CONVENIENCE RECEPTACLES AND PROVIDE BLANK <br /> 17 20/1 FLY TRAP BAKERY 0.4 A 0.90 A 0.5 RECPT CAFE 20/1 18 17 15/1 CAMERA REGISTER 0.4 A 1.36 A 1.0 RECEPT-TECH ROOM 20/1 18 SUBMISSION OF BID AND FIELD VERIFY ALL COVERS OVER REMAINING RECEPTACLE BOXES. ALL <br /> 19 20/1 MICROWAVE 317 1 A 3.10 A 2.1 20 19 15/1 RECEPT- FLORAL 0.2 A 0.58 A 0.4 RECEPT-SEC OFFICE 20/1 20 EXISTING CONDITIONS AND EXTENT OF DEMOLITION CIRCUITRY TO BE RE-USED FOR NEW WORK AS <br /> %47 <br /> WORK. SHOWN ON 2/E6.1. <br /> PROOF BOX 124E 30/2 500 WEST CAPITOL AVENUE <br /> 21 20/1 MICROWAVE 317 1.5 A 3.60 A 2.1 22 21 20/1 RECEPT- PHARMACY 0.4 A 0.96 A 0.6 RECEPT- MEAT PREP 20/1 22 E. CONTRACTOR TO REMOVE ALL EXISTING ELECTRICAL 6. EXISTING DEVICE AND CIRCUIT TO REMAIN. W. SACRAMENTO, CA 95605 <br /> 23 20/1 BLENDER 31 OF 0.6 A 0.80 B 0.2 INTERLOCK CONTROL AH-4 20/1 24 23 20/1 RECEPT- PHARMACY 0.4 A 1.16 D 0.8 HOT WOK SCALE 20/1 24 CIRCUITRY, CONDUIT, WIRE BOXES, ETC. AS SHOWN INTERCEPT AND EXTEND EXISTING UPS CIRCUIT TO P.O. BOX 15618 <br /> 25 20/1 BLENDER 310E 0.6 A 1.80 A 1.2 COFFEE GRINDER 3108 20/1 26 25 20/1 RECEIPTON DRAWINGS. ALL CIRCUITRY TO BE REUSED WILL NEW EMERGENCY POWER DEVICES SHOWN ON SACRAMENTO, CA 95852- PHARMACY 0.4 A 1.16 D 0.$ DELI SCALES 20/1 26 BE RELOCATED AS REQUIRED TO ACCOMMODATE 2/E6.1. <br /> 27 20/1 SPARE SPARE 20/1 28 27 20/1 RECEPT- PHARMACY 0.4 A 0.56 A 0.2 PRODUCE SCALE REG 20/1 28 NEW ELECTRICAL LAYOUT PER DRAWINGS. REVISIONS <br /> CONTRACTOR SHALL PROVIDE ALL NEW DEVICES 7. NET LOAD INCREASED ON EXISTING CIRCUIT BY <br /> 29 20/1 SPARE SPARE 20/1 30 29 20/1 RECEPT- PHARMACY 0.4 A 0.36 SPARE 20/1 30 THROUGHOUT SCOPE AREA. 0.54 KVA. <br /> 31 2.4 B 3.20 A 0.8 RECPT CAKE COMPUTER 20/1 32 31 20/1 RECEPT- PHARMACY 0.4 A 1.16 A 0.8 RECEPT- RCV DESK 20/1 32 F. CONTRACTOR IS RESPONSIBLE FOR DEMO OF ALL 8. DEVICE SHALL BE SURFACE MOUNTED. <br /> 0 40/2 (N)CASE <br /> 4L�k <br /> 33 2.4 B 2.40 SPARE 20/1 34 33 20/1 RECEPT- BOOK KEEPER 0.8 A 1.10 A 0.3 RECEPT-521 B 20/1 34 EXISTING FLORAL REFRIGERATED CASE CIRCUIT ANDCONTROL WIRING. ALL ELECTRICAL AND CONTROL 9. DEVICE SHALL BE SURFACE MOUNTED BELOW <br /> 35 1.9 D 2.10 D 0.2 MICROWAVE 317 20/1 36 35 20/1 RECEPT- IDF BACKBOARD 0.2 A 0.18 SPARE 20/1 36 CIRCUITS TO BE RE-USED WILL BE RELOCATED AS WINDOW GLAZING. <br /> 30/2 ESPRESSO MACH 310D REQUIRED TO ACCOMMODATE NEW CASE <br /> 37 1.9 D 3.70 D 1.8 38 37 SPARE 20/1 38 <br /> 4L�k <br /> PANINNI 30/2 LOCATIONS. 10. EXISTING DEVICE TO BE BLANKED OFF AND B4L�k <br /> OX 39 1.2 B 3.00 D 1.8 40 39 30/3 TVSS SPARE 20/1 40 TO BE ABANDONED. <br /> 20/2 (N)CASE G. CONTRACTOR TO PROVIDE 120V 20A IG <br /> 41 1.2 B 1.20 SPARE 20/1 42 41 1 SPARE 20/1 42 RECEPTACLES FOR ALL UPS POWER CIRCUITS. <br /> DEVICES TO BE ORANGE IN COLOR. ALL WIRING ( k <br /> CONNECTED LOAD PER PHASE 16.40 14.50 7.60 CONNECTED LOAD PER PHASE 4.44 5.08 4.36 FOR UPS CIRCUITS TO BE STRIPED PER RALEY'S <br /> LOAD SUMMARY CONN. DEMAND DEMAND LOAD SUMMARY CONN. DEMAND DEMAND SPECIFICATIONS. 4L�k <br /> KVA FACTOR KVA VOLTS: 120/208V,3PH,4W PANEL KVA FACTOR KVA VOLTS: 120/208V,3PH,4W PANEL H. CONTRACTOR TO PROVIDE ANY/ALL REQUIRED DATA 4L�k <br /> TYPE "A": RECEPTACLES (FIRST 10KVA) 10.00 100% 10.00 MAIN C.B.: MLO (E) TYPE "A": RECEPTACLES (FIRST 10KVA) 10.00 100% 10.00 MAIN C.B.: MLO (E) CHASES FOR ALL DATA LOCATIONS. COORDINATE <br /> REQUIREMENTS WITH RALEY'S SPECIFICATIONS. <br /> TYPE "A": RECEPTACLES (OVER 10KVA) 13.50 50% 6.75 BUS: 225 AMP TYPE "A": RECEPTACLES (OVER 10KVA) 1.08 50% 0.54 BUS: 125 AMP 4L�k <br /> TYPE "B": NON-CONTINUOUS LOADS 7.40 100% 7.40 POLES: 84 (TWO SECTIONS) B TYPE "B": NON-CONTINUOUS LOADS 100% POLES: 42 UPS1 I. CONTRACTOR TO REVISE ANY/ALL PANEL /r <br /> SCHEDULES AS REQUIRED BY SCOPE OF WORK ! <br /> TYPE "C": CONTINUOUS LOADS 125% MOUNTING: RECESSED SECT 1 TYPE "C": CONTINUOUS LOADS 125% MOUNTING: RECESSED AND IDENTIFY/LABEL ALL DEVICES PER RALEY'S <br /> TYPE "D": KITCHEN EQUIPMENT 7.60 65% 4.94 AIC RATING: (E) KA TYPE "D": KITCHEN EQUIPMENT 2.80 65% 1.82 AIC RATING: (E)10 KA SPECIFICATIONS. <br /> TOTAL DEMAND LOAD KVA O O SUBFEED: (E)SECTION 2 O TOTAL DEMAND LOAD KVA 13.88 12.36 SUBFEED C.B.: N/A O J CONTRACTOR <br /> ONTDRAWRAC ONCIS RESPONIN SIBLE <br /> FOR REVION EWING <br /> FO RLL <br /> TOTAL DEMAND LOAD AMPS TOTAL DEMAND LOAD AMPS 34.33 ANY/ALL ELECTRICAL OR CONTROL REQUIREMENTS. <br /> K. CONTRACTOR TO CORE DRILL OUT ANY ABANDONED LI-I M A <br /> CONDUITS ON SALES FLOOR AND PATCH. r -, <br /> anginears for a sustainablefuture <br /> L. EXISTING LIGHTING IN ALL SCOPE OF WORK TO L <br /> REMAIN IN PLACE. <br /> 910 Glenn Drive <br /> Folsom,CA 95630 <br /> M. SEE SHEET E3.1 FOR PANELBOARD LOCATIONS. T.916.934.5103 www.glumac.com <br /> Project Manager: LK <br /> Engineer/Designer: GD/BS <br /> POLE C.B. SERVICE LOAD KVA SERVICE C.B. POLE Job Number: P21US285917 <br /> NO. AMP/P TOTAL TYPE A B C TYPE TOTAL AMP/P NO. ��QROfESS/p�i� <br /> 43 2.1 A 4.10 D 2 44 <br /> 45 30/3 HOBART TURBO WASH 2.1 A 4.10 D 2 OVEN 122D 30/3 46 11 I ,� No. 107 <br /> 47 2.1 A 4.10 D 2 48 <br /> L� o i <br /> J J EE \Q <br /> 49 0.5 B 1.10 B 0.6 REF-5 20/1 50 \� // \ 3/4"C 3#8 & #10G grFOF CAI�F��� <br /> 51 20/3 AH-5 0.5 B 1.10 B 0.6 REF-3 20/1 52 <br /> 0 <br /> 53 0.5 B 0.50 SPARE 20/1 54 \ B-73,75 B-39,41 B-31,33 <br /> 55 0.5 B 2.30 D 1.8 56 <br /> PANINNI 30/2 <br /> 57 20/3 AH-4 0.5 B 2.30 D 1.8 58 <br /> 59 0.5 B 0.50 60 <br /> B-81,83 J <br /> 61 50/2 DUAL BREWER 310A 2 D 2.00 SPARE 30/3 62 8-78 B-76,78 /-UPS1-1 1 <br /> E31 <br /> C .63 2 D 2.00 64 g-76 /' (E) <br /> 65 2 D 2.00 66 i <br /> 50/2 DUAL BREWER 310A <br /> 67 2 D 2.00 SPARE 30/3 68 UPS1-11 <br /> 69 20/1 RECPT SODA SUBSHOP 0.7 A 0.70 70 B-77,79 J <br /> 71 20/1 RECPT ICE SUBSHOP 0.8 A 0.80 72 <br /> SPARE 20/2 <br /> 73 1.2 B 1.20 74 <br /> O3 20/2 (N)CASE <br /> 75 1.2 B 2.30 A 1.1 MICROWAVE 317 20/1 76 <br /> UPS1-1 1 <br /> 77 1.2 B 1.80 A 0.6 WARMING TOASTER 310H 20/1 78 +45' <br /> O3 20/2 (N)CASE <br /> 79 1.2 B 1.20 SPARE 20/1 80 <br /> 81 20/2 (N)CASE ® <br /> 1.2 B 1.20 SPARE 20/1 82 9 B-16 <br /> 83 1.2 B 1.20 SPARE 20/1 84 (D- +45 <br /> ® <br /> CONNECTED LOAD PER PHASE 13.90 13.70 10.90 <br /> UPS1-11 � ® ® g_18 <br /> B-18 +80" <br /> LOAD SUMMARY CONN. DEMAND DEMAND Q - <br /> KVA FACTOR KVA VOLTS: 120/208V,3PH,4W PANEL - <br /> ❑ 9 B-16 <br /> TYPE "A": RECEPTACLES (FIRST 10KVA) 9.50 100% 9.50 MAIN C.B.: MLO (E) <br /> TYPE "A": RECEPTACLES (OVER 10KVA) 50% BUS: 225 AMP <br /> TYPE "B": NON-CONTINUOUS LOADS 11.40 100% 11.40 POLES: 84 (TWO SECTIONS) B <br /> TYPE "C": CONTINUOUS LOADS 125% MOUNTING: RECESSED SECT 2 <br /> TYPE "D": KITCHEN EQUIPMENT 17.60 65% 11.44 AIC RATING: (E) KA <br /> TOTAL DEMAND LOAD KVA 77.00 61.43 SUBFEED C.B.: N/A PROJECT <br /> TOTAL DEMAND LOAD AMPS 170.64 NORTH <br /> 2 ENLARGED POWER REMODEL PLAN - ECART AREA <br /> SCALE. 1/4"=l'-O" <br /> 0 2' 4' 8' <br /> SHEET TITLE <br /> ENLARGED ELECTRICAL PLANS <br /> AND PANEL SCHEDULES <br /> B-76,78 (RL) <br /> p r / <br /> \\ <br /> rB-78 �6B-18 <br /> ) R) I �� (R) <br /> LL �`J� /'(RL) <br /> L- - - - - - - - -ID - - - - - - � <br /> B-16,18 <br /> Y 4 B-18 <br /> L(::::); E31 �'� j�>�� � � L J (R) �PROJECT NAME <br /> UPS1-1 1 � > �r _ --f � <br /> RALEY S/ <br /> BEL AIR/ <br /> UPS1-11 k NOB HILL <br /> Lz � > � � >�� FOOD SOURCE <br /> TYP. STORE <br /> B-16 # 306 <br /> (R) <br /> (� - - NIL - - !�,TL - - �1- B-31,32 � <br /> F - - ® - - ��_ _� �_ _�I I 4255 MORADA LANE <br /> 7� 7� STOCKTON, CA 95212 <br /> �II I I III I I I � <br /> I (R) 1 II II _ B-18 � 1 � <br /> / � zJ <br /> PROJECT N0. <br /> � � P21US285917 <br /> E7 r) - =[E] D <br /> DRAWN BY <br /> GD/BS <br /> SCALE <br /> PROJECT PROJECT <br /> AS SHOWN <br /> NORTH NORTH <br /> ENLARGED POWER DEMOLITION PLAN - ECART AREA ENLARGED POWER DEMOLITION PLAN - CAFE AREA <br /> 3 SCALE. 1/4"=1'-0" SCALE. 1/4"=1'-0" DATE <br /> 0 2' 4' 8' 0 2' 4' 8' 04-06-2021 <br /> PAGE NO. <br /> E6 . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.