HEAT PUMP PACKAGE ROOFTOP UNIT SCHEDULE - ALTERNATE CLIENT: <br /> LEGEND b <br /> COOLING CONDENSING HEATING INDOOR FAN ELECTRICAL DATA <br /> MARK MANUFACTURER/MODEL # SERVICE NOMINAL TOTAL SENSIBLE ENT. AIR ENT. AIR4TF 17'F BHp WEIGHT MIN. OUTSIDE SYMBOL ABBREVIATION DESCRIPTION <br /> TONS MBH MBH DB, 'F WB, 'F EER SEER TEMP., 'F MBH MBH COP CFM IN WG (HP) VOLTS PHASE F REQ. C RMLAPR. MCA MOCP (LBS-) AIR CFM LOCATION REMARKS f <br /> RTU "YORK" XP102 STORE SA/SUP SUPPLY AIR (RISE/DROP) <br /> 8.5 104.1 80.4 80.0 67.0 11.2 - 95 90.5 53.0 3.35/2.25 3,400 0.6 1.69 208 3 60 14.5 53.8 70 1,350 330 ROOF 1 2 3 4 5 5 7 8 9 10 11 RA/RET RETURN AIR DUCT (RISE/DROP) <br /> EA/EXH EXHAUST AIR DUCT (RISE/DROP) <br /> RTU "YORK" XPO60 STORE 5.0 59.8 59.8 45.3 67.0 10.6 13.0 95 56.5 L4.4 _ 3.10/2.10 2,000 0.6 1.03 208 3 60 14.1 25.1 35.0 800 130 ROOF (D(23 4 5 6 7 8 9 10 11 CEILING DIFFUSER/SUPPLY REGISTER <br /> 2 <br /> ® - CD/5R (ARROWHEAD REPRESENTS NUMBER OF THROW) <br /> U1 HEAT PUMP PACKAGED ROOFTOP UNIT. ® DUCT SMOKE DETECTOR IN SUPPLY AIR ® PROVIDE THE FOLLOWING FACTORY INSTALLED OPTIONS: 10 FACTORY INSTALLED POWER EXHAUST. ( 4-WAY TYPICAL IF NO ARROWS) <br /> PLENUM. A. 12" HIGH ROOF CURB. THIS UNIT WILL BE USED IN AREAS WHERE ® --w- RR/RG RETURN REGISTER/GRILLE <br /> HIGH 2 HEAT TYPE EFFICIENCY,ROOFTOP <br /> INDOOR FAN, LOW 5 PROVIDE PROGRAMMABLE THERMOSTAT. B. CRANKCASE COMPRESSOR HEATER START KIT. 11 DISCONNECT SWITCH. THERE IS NO GAS AVAILABLE. <br /> O O ® -+� ER/EG EXHAUST REGISTER/GRILLE <br /> SET MINIMUM RTU FRESH AIR PER T-24 ® R-410 REFRIGERANT. D. DIUALR1115VKGFCI CONVENIENCE OUTLET. RECTANGULAR DUCT ELBOW WITH TURNING VANES <br /> O REQUIREMENT. - FC FLEXIBLE CONNECTION <br /> (DMERV 8 FILTERS ® ECONOMIZER <br /> �- (L) DUCT LINING (1" THICK UNLESS OTHERWISE NOTED) <br /> SINGLE LINE DUCT BRANCH TAKE-OFF <br /> DUCT TRANSITION (RECTANGULAR TO ROUND) ARCA <br /> FLEX FLEXIBLE DUCT (5'-0 MAXIMUM) <br /> T T-STAT PROGRAMMABLE THERMOSTAT BP WEST COAST PRODUCTS,LLC <br /> S TEMPERATURE SENSOR <br /> (D4 CO2 SENSOR <br /> SD SD DUCT SMOKE DETECTOR R <br /> Hl� MD MECHANICAL DAMPER / T <br /> 0 DIA. DIAMETER W <br /> O FURNISHED AND INSTALLED BY MECHANICAL <br /> CONTRACTOR. V <br /> O FURNISHED AND INSTALLED BY ELECTRICAL Z <br /> CONTRACTOR. �(� C" <br /> FURNISHED BY MECHANICAL CONTRACTOR AND triENC*1N� � <br /> ME INSTALLED BY ELECTRICAL CONTRACTOR. HG <br /> P.O.C. POINT OF CONNECTION 18215 72ND AVENUE SOUTH <br /> KENT, WA 98032 <br /> SD-1 (SD-SUPPLY DIFFUSER, RD-RETURN DIFFUSER, E---EXHAUST) (425)251-6222 <br /> EXHAUST FAN SCHEDULE GENERAL NOTES 100 -- -- AIR QUANTITY IN CFM (425)251-8782 FAX <br /> CIVIL ENGINEERING, LAND PLANNING, <br /> SURVEYING, ENVIRONMENTAL SERVICES <br /> EXHAUST EXT. STATIC ELECTRICAL DATA 1. CONSTRUCTION TO CONFORM WITH: T=-- <br /> MECHANICAL EQUIPMENT DESIGNATION NO. DATE REVISION DESCRIPTION <br /> M OTO R <br /> MARK SERVICE LOCATION AIR PRESSURE RPM WEIGHT MANUFACTURER & MODEL # REMARKS DESIGNATED NUMBER <br /> CFM IN. W.G. WATTS VOLTS PHASE Hz LBS. <br /> - CURRENT STATE BUILDING CODE, WITH LOCAL AMENDMENTS <br /> HP - CURRENT STATE MECHANICAL CODE, WITH LOCAL AMENDMENTS <br /> KEF TYPE 2 - CURRENT STATE PLUMBING CODE. WITH LOCAL AMENDMENTS A/C , AC AIR CONDITIONING <br /> 1 HOOD ROOF 650 0.500 1 .328 (1/2) 115 1 60 56 "CAPTIVEAIRE" DU33HFA 3 4 5 7 a - CURRENT STATE ELECTRICAL CODE, WITH LOCAL AMENDMENTS BDD BACK DRAFT DAMPER <br /> - CURRENT STATE FIRE CODE, WITH LOCAL AMENDMENTS <br /> GREEN <br /> 1 <br /> RESTROOMS CEILING 100 0.250 - 100 115 1 60 11 <br /> - CURRENT STATE ENERGY CODE, WITH LOCAL AMENDMENTS CB CIRCUIT BREAKER F HECK CSP--8110 1 2 3 ® 4 <br /> " 2. THE CONTRACTOR IS RESPONSIBLE FOR PERMIT FEES. CLG• CEILING <br /> EF SLUSH ROOF 500 0.375 936 (1/4) 115 1 60 11 "CAPTIVEAIRE" DR30HFA 3 4 5 7 8 CONN. CONNECT/CONNECTION <br /> 2 MACHINE �� 3, THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, e <br /> TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF THE WORK. CONT. CONTINUATION <br /> ALL MATERIALS AND WORK SHALL COMPLY WITH APPLICABLE CODES AND <br /> CONT'R CONTRACTOR <br /> (D CEILING MOUNTED EXHAUST FAN. O MUSHROOM TYPE FAN. GOVERNING REGULATIONS AND MEET THE APPROVAL OF THE LOCAL <br /> O INTERLOCK WITH LIGHT FIXTURE. ® SPEED CONTROLLER, JURISDICTION. CFM CUBIC FEET PER MINUTE <br /> 4. ANY MATERIAL, ARTICLE OR PIECE OF EQUIPMENT OTHER THAN THAT CU CONDENSING UNIT <br /> �3 WITH BACKDRAFT DAMPER. O7 PROVIDE WITH 12 ROOF CURB. INDICATED SHALL NOT BE USED UNLESS APPROVED IN WRITING BY THE DET. DETAIL <br /> ENGINEER AND ANY CHANGES IN MECHANICAL, ELECTRICAL AND/OR OTHER DISC. DISCONNECT <br /> ® WITH FLEXIBLE DUCT CONNECTION. ® DISCONNECT SWITCH. SYSTEMS REQUIRED DUE TO SUCH SUBSTITUTION SHALL BE THE SEAL: <br /> RESPONSIBILITY OF THE HVAC CONTRACTOR; AND AT NO ADDITIONAL COST TO DTR DOWN THRU ROOF QRQ<ES5/p <br /> THE OWNER. EF EXHAUST FAN <br /> 5_ TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE MATERIALS BEFORE, <br /> AIR DEVICE SCHEDULE DURING AND AFTER INSTALLATION. IN THE EVENT OF DAMAGE, IMMEDIATELY (E) EXISTING <br /> REPAIR ALL DAMAGED AND DEFECTIVE WORK TO THE APPROVAL OF THE E.A.T. ENTERING AIR TEMPERATURE o <br /> DIFFUSER FACE <br /> TYPE MOUNTING DUTY ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. GA. GAGE/GAUGE - <br /> ORv' Ld 6. THREE SETS OF OPERATING AND MAINTENANCE MANUALS SHALL BEGC GENERAL CONTRACTOR <br /> ui <br /> yctR+cl�� <br /> NECK CFM w Lu � u >- z cn L, SUBMITTED UPON COMPLETION OF PROJECT. <br /> MARK CEILING GRID u) � w LSI z Q J O <br /> SIZE RANGE D cn � ] LL a_ ? ¢ z MFR. MODEL NO. REMARKS GF GAS FURNACE OF C A�\F <br /> SIZE (INCHES) L o r = a 7. IN ADDITION TO EQUIPMENT WARRANTIES FURNISH A WRITTEN GUARANTEE <br /> (n cn of w AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR. HVAC HEATING, VENTILATING, AND AIR CONDITIONING <br /> Date Signed: March 11, 2017 <br /> GUARANTEE SHALL INCLUDE REPAIR OF DAMAGE TO, OR REPLACEMENT OF, MCA MINIMUM CIRCUIT AMPACITY <br /> ANY PART OF EQUIPMENT OR PREMISES CAUSED BY EQUIPMENT PROVIDED. <br /> SD-1 8710 12"x12" 90 X - - - X - X - - - TITUS PAS 1 2 3 MFR. MANUFACTURER SA <br /> SD-2 12"0 24"x24" 200-270 X - -- - X - X - - - TITUS PAS1 2 3 comz&r 4, <br /> MECH. MECHANICAL c EnRv�Ei� <br /> cowsuc ra <br /> MOCP MAXIMUM OVERCURRENT PROTECTION 10555 old Placerville Road <br /> SD-3 12"0 27"0 400-500 X - - - - X X - - - TITUS TM RA1 2 3 <br /> Sacramento, CA 95827-2503 <br /> (N) NEW Phone: (916) 368-4468 <br /> Fax: (916)368-4490 <br /> RD-1 - 24"x24" 800-1000 X - - - X - - X - - TITUS PAR 1 2 3 <br /> OA/OSA OUTSIDE AIR www.saceng.com <br /> PH PHASE Jab No. 17189 <br /> O PROVIDE OPPOSED BLADE DAMPER, RAD RETURN AIR DUCT DEVELOPMENT INFORMATION: <br /> 20 TYPE AND CFM SHALL BE AS INDICATED ON DRAWING SAD SUPPLY AIR DUCT ARCO NTI <br /> 1/M-2.1 AT EACH AIR DEVICE. S/S STAINLESS STEEL <br /> 2900 am/pm <br /> O SELECTION OF THE FINISHES OF AIR DISTRIBUTION TYP. TYPICAL 26'X3$' CAR WASH <br /> DEVICES BY INTERIOR DESIGNER/ARCHITECT. UON UNLESS OTHERWISE NOTED FUEL CANOPY <br /> UTR UP THRU ROOF w/ 8 MPD's <br /> V VOLTS <br /> AIR CURTAIN SCHEDULE SITE ADDRESS: <br /> FAN ELECTRICAL ACOUSTICS DIMENSIONS {in) DRAWING SCHEDULE 1904 DANIELS STREET <br /> MARK MANUFACTURER & SERVICE MEASURE 10 FROM WEIGHT REMARKS <br /> MODEL MAX. FPM MAX. CFM MOTORS FLA VOLTAGE PHASE Hz NOZZLE LENGTH DEPTH (LBS) @ FfSMATECANTECA,CA <br /> HIPROAD <br /> SHEET NUMBER DESCRIPTION <br /> AC MARS 3,950 2,920 TWO 1/2 10.2 115 1 60 ENTRY DOOR fib 72 26 105 1 2 FACILITY # TBD <br /> 1 PH1072-2U-PW <br /> MOA LEGEND, GENERAL NOTES & SCHEDULES <br /> DESIGNED BY. <br /> MO.2 MECHANICAL SPECIFICATIONS <br /> CHECKM BY: <br /> O1 MICROSWITCH CONTROL. MOUNT SWITCH SUCH THAT M0.3 MECHANICAL T-24 FORMS DRAWN BY: <br /> AIR CURTAIN STARTS WHEN DOOR OPENS. <br /> MO.4 MECHANICAL T-24 FORMS VERSION: PROJECT NO: <br /> O SELECTION OF THE FINISHES OF AIR CURTAIN BY <br /> INTERIOR DESIGNER/ARCHITECT. MO.5 MECHANICAL T-24 FORMS 16932 <br /> DRAWING TITLE: <br /> M2.1 MECHANICAL FLOOR PLAN <br /> EQUIP. SCHED. <br /> M2.2 MECHANICAL ROOF PLAN <br /> M6.1 MECHANICAL DETAILS LEGEND, NOTES <br /> M6.2 HOOD & FANS SHOP DRAWING SHEET NO: <br /> M9.1 CONTROLS <br /> momi <br />