Laserfiche WebLink
I <br />' TABLE 4 AIR SPARGING PILOT TEST APPLIED PRESSURE AND FL WRATE DATA <br /> FORMER EXXON RETAIL SITE 7-3942 <br />' 4444 NORTH PERSHING AVENUE,STOCKTON,CALIFORNIA <br /> Sparging Applied Air Temperature Air <br />' Well Pressure Flow Rate Flow Rate <br /> Number Date/Time (psi) (cfm) (OF) (scfm) <br /> SWI 9/8/0413 38 90 108 1350 155 <br /> SWI 9/8/04 13 53 60 107 1470 132 <br />' <br /> SWI 9/g/041410 60 110 1460 136 <br /> SWI 9/8/041435 60 111 1461 137 <br /> UVB-MW 1 9/8/041510 90 107 1302 155 <br /> UVB-MW 1 918/041530 60 11 1 1453 137 <br /> UVB-MWI 9/8/041602 60 112 1461 13 8 <br /> Standard air flow rate(scfm)= Actual air flow rate(cfm)X Actual pressure(in H2O)X Standard temperature(K) <br /> Standard pressure (in H2O)X Actual temperature(K) <br /> I cfm cubic feet per minute <br /> scfm standard cubic feet per minute <br /> OF Fahrenheit <br /> psi pounds per square inch <br /> r• <br /> i <br /> i <br /> i <br /> i <br /> i <br /> G T.jmts%73942\MASTER\WPIASR0904tAlot Tcst Data(8 Sept 2004) Pap 1 of i <br />