� . PROTOCOLS FOR QUARTERLY GROUNDWATER MONITORING <br />' GROUNDWATER GAUGING <br /> Wells are opened prior to gauging to allow the groundwater level in the wells to equilibrate with <br />' atmospheric pressure The depth to groundwater and depth to liquid-phase hydrocarbons,if present, <br /> are then measured to the nearest 0 01 feet using an electronic water level meter or optical interface <br /> probe The measurements are made from a permanent reference point at the top of the well casing <br /> If less than 1 foot of water is measured in a well,the water is bailed and, if the well does not recover, <br /> the well is considered "dry " Wells with a sheen or measurable liquid-phase hydrocarbons are <br /> generally not purged or sampled <br />' WELL PURGING <br />' After the wells are gauged,each well is purged of approximately 3 well casing volumes of water to <br /> provide representative groundwater samples for analysis Field parameters ofpH, temperature, and <br /> electncal conductance are measured dunng purging to ensure that these parameters have stabilized <br />' before groundwater in a well is sampled. Groundwater in each well is purged using an inertial pump <br /> (WaTerra), an electric submersible pump, or a bailer After the well is purged, the water level is <br /> checked to ensure that the well has recharged to at least 80 percent of its original water level <br />' GROUNDWATER SAMPLING <br /> After purging, groundwater in each well is sampled using dedicated tubing and an inertial pump <br />' (WaTerra) or a factory-cleaned disposable bailer Samples from extraction wells are typically <br />' collected from sample ports associated with the groundwater remediation system Samples collected <br /> for volatile organic analysis are placed in Teflon septum-sealed 40-milliliter glass vials Samples <br /> collected for diesel analysis are placed in 1-liter amber glass bottles Each sample bottle is labeled <br />' with the site name,well number, date,sampler's initials,and preservative The samples are placed in <br /> a cooler with ice for delivery to a state-certified laboratory The information for each sample is <br /> entered on a chain-of-custody form prior to transport to the laboratory <br /> I <br />' G Trojects\ExxonMobtl\Maswr\ExxonMobil QMR templateslQMR protocols-purge waterra doc <br />