My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006146
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4444
>
2900 - Site Mitigation Program
>
PR0540885
>
ARCHIVED REPORTS_XR0006146
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2020 5:09:59 PM
Creation date
4/10/2020 2:24:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006146
RECORD_ID
PR0540885
PE
2960
FACILITY_ID
FA0023381
FACILITY_NAME
FORMER EXXON SERVICE STATION NO 73942
STREET_NUMBER
4444
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11022017
CURRENT_STATUS
01
SITE_LOCATION
4444 N PERSHING AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 3.2 1 California Water Service Company Records <br /> As part of the well search in the vicinity of former Exxon RS 7-3942, a database printout was <br /> requested and received from the California Water Service Company (Cal Water) in April 2001 <br /> Among the two State Wells (Sta 38 and Sta 49) identified within one mile of former Exxon RS <br />' 7-3942, only Sta 49 is active Well Sta 38 is located crossgradient and approximately 1,800 <br /> feet southwest from former Exxon RS 7-3942, and Well Sta 49 is located upgradient and <br /> approximately 1,900 feet south from the site Both wells are more than 500 feet deep and <br /> screened from depths greater than 150 feet The information provided by Cal Water suggests <br /> that there are no wells that pump water from a shallow or deeper water bearing zone within one <br />' mile of the site in the downgradient direction The Cal Water data record is provided in <br /> Appendix H The location of these wells is presented on Figure 9 <br /> 3.2.2 Environmental Data Resources, Inc. Records <br /> An electronic search of environmental records for sensitive receptors was performed by <br /> Environmental Data Resources, Inc (EDR) The EDR records, as presented in Appendix I, <br /> indicate five downgradient water wells located approximately 4,800 feet northeast (reported as <br /> destroyed), and six wells 1,300 feet southeast and upgradient of the site The location of these <br />' wells is presented on Figure 9 There are groundwater monitoring wells located at both the Shell <br /> service station and a 7-11 food and gasoline service store located on the southwest and northwest <br /> corners, respectively, of the intersection of North Pershing Avenue and Rosemarie Lane <br /> 3.2.3 Field Observations <br /> A limited door-to-door well survey was performed by ETIC in the immediate area of the site to <br /> determine the number of groundwater monitoring wells at the neighboring properties, and to <br /> assess the presence of a domestic well thought to exist in a location approximately 600 feet west <br /> of the site, which is upgradient to crossgradient of the site The potential presence of a domestic <br /> well at this location was reported in the Preliminary Report prepared in 1987 (EA 1987a) <br /> There are 5 groundwater monitoring wells located at the Shell service station and 3 wells at the <br /> 7-11 food and gasoline service store located on the southwest and northwest corners, <br /> respectively, of the intersection of North Pershing Avenue and Rosemarie Lane The property <br /> where the domestic well was thought to be located was visited by ETIC personnel As no one <br /> was available to interview at the time of the visit, a written request for information concerning <br /> the presence or absence of the well was left at the property ETIC did not receive a response to <br /> the written request The location of this property in question is presented in Appendix J <br /> G 1Projectst73942'64A3FER%WP1Ra08014ext2 doc 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.