Laserfiche WebLink
' LABORATORY NARRATIVE <br /> TO-14 <br />' ETIC Engineering <br /> Workorder#0101040 <br />' Sixteen 6 Liter Summa Canister samples were received on January ry 03 2001 The laboratory <br /> performed analysis via EPA Method TO-14 using GC/MS in the full scan mode The method involves <br />' concentrating up to 0 S liters of air The concentrated aliquot is then flash vaporized and swept <br /> through a water management system to remove water vapor Following dehumidification, the sample <br /> passes directly into the GC/MS for analysis See the data sheets for the' reporting limits for each compound <br />' During the five point calibration, two low-level standards are used The low-level standard for TO-14- <br /> compounds is spiked at 0 5 ppbv and represents the reporting limit for these compounds The <br /> low-level standard for the non-TO-14 compounds is spiked at 2 0 ppbv and represents the reporting <br />' limit for these compounds The TO-14 compounds are present in both standards but are excluded from <br /> reporting in the 2 0 ppbv standard since a lower level is already included in the curve <br />' Method modifications taken to run these samples include <br /> Requirement TO-14 ATL Modifications <br /> Internal standard retention Not specified Within 0 50 minutes of most recent daily CCV internal <br />' times standards <br /> Internal standard recoveries Not specified Within 40% of the daily CCV internal standard area for <br /> blanks and samples <br /> Internal standard retention Not specified Within 0 50 minutes of most recent daily CCV internal <br /> times standards <br />' Internal calibration criteria Not specified RSD of 30% or less for standard compounds,40% or less <br /> for non-standard and polar compounds <br /> Cantinuins calibration Not specified 70- 130% for at least 90% of standard compounds,60- <br /> verification criteria 140% for at least 30% of non-standard and polar <br />' compounds <br /> Response factor for Average response Average response factor(ICAL) <br /> quantitation tactor(ICAL) <br /> I <br /> Receivin Notes <br />' There were no receiving discrepancies <br />' Analytical, Notes <br /> The Methanol standard analyzed on 01/07/01 was one day outside the 3 day hold specified in the <br /> TO 14 SOP The standard was recertified on 1/08/Oland met all QC requirements <br />' Definition of Data Qualifying Flags <br /> Seven qualifiers may have been used on the data analysis sheets and indicates as follows <br /> B - Compound present in laboratory blank greater than reporting limit(back-round subtraction not <br /> In <br /> pertormed) <br />' 7 - Estimated value <br /> E - Exceeds instrument calibiation range <br /> S - Saturated peak <br />' Q - Exceeds quality control limits <br />