Laserfiche WebLink
HOUSTON LABOi <br /> 9800 INT£iCHANGE5 DRIVE <br /> HOUSTON TEXAS 77054 <br /> Ole ® (713)660-0901 <br /> Quality Control Report <br />. EXXON Company U S A. <br /> UP3942 1 <br /> 4nalysis Purgeable Aromatics WorkOrder 00090294 <br /> Ulethod SW8021B Lab Batch la 821082 <br /> Matrix Spike(MSI!Matrix Spike DupScatg(M_PI <br /> Sample Spliced 00090421-01 <br /> Runlp HP_N_ODMUA408759 Units ug/L <br /> Analysis Date 09!20!20001223 Analyst DL <br /> Analyte Sample Result AAS MS Result MS% MSD MSD Result MSD% RPD RPD Low Hlgh <br /> Spike Recovery Splice Recovery Limit Limit Limit <br /> Added Added <br /> oluene NO 20 18 90 8 20 19 940 345 20 38 159 <br /> I,p-Xylene NO 40 351 8861 40 38 939 5801 17 53 144 <br /> Xylene ND 20 18 8831 20 19 925 4 661- 18 53 143 <br /> yienes,Total NDI 60 53 8831 W 57 950 72-71 1 5j 53 1 ` <br /> 1 <br /> infers NDIU-Not Detected at the Reporting Limit '-Recovery Outside Advisable QC Limits <br /> 8-Analyte detected in the associated Method Blank D-Recovery Unrepactable due to Dilution <br /> J-Estimated value between MDL and PQL MI-Matnx interference <br /> 9/21100 1 43 54 FIM <br />