HOUSTON LABORATORY <br /> 8HO HOUSTON, <br /> TEXAS DRIVE <br /> HOUSTON,TEXAS 77054 <br /> ® (713)8604901 <br /> • Client Sample ID UVBMW-2 Collected 2129100 2 15 00 SPL Sample ID 00030103-15 <br /> Site 7-3942,19909830 <br /> Analyses/Method Result Rep Limit DII Factor QUAL Date Analyzed Analyst Seq # <br /> GASOLINE RANGE ORGANICS MCL CA GRO Units u IL <br /> Gasoline Range Organics 320 50 1 03/11/00 3 W LJ 215655 <br /> Sun- 1,4-1)lfluorobenzene 107 % 62-144 1 03/11/00 3 17 LJ 215655 <br /> _Surr 4-Bromofluorobenzene 991 % 44-153 1 03/11/00 3 17 LJ 215655 <br /> PURGEABLE AROMATICS MCL SW8021B Units u 1L <br /> Benzene - — 27 1 1 03/07/00 18 55 CJ 211580 <br /> Ethylbenzene 67 1 1 03/07/00 18 55 CJ 211580 <br /> Metnyl tort-butyl ether ND 1 1 03/07/00 18 55 CJ 211580 <br /> Toluene 12 1 1 03/07/00 18 55 CJ 211580 <br /> m p-Xylene 52 1 1 03/07/00 18 55 CJ 211580 <br /> o-Xylene ND 1 1 03/07/00 18 55 CJ 211580 <br /> Xylenes,Total 52 1 1 03/07/00 18 55 CJ 211580 <br /> Surr 1,4-Difluorobenzene 102 % 72-137 1 03/07/00 18 55 CJ 211580 <br /> Surr 4-Bromofluorobenzene 105 % 48-156 1 03/07/00 18 55 CJ 211580 <br /> 0 - <br /> Qualifiers NDIU-Not Detected at the Reporting Limit >MCL-Result Over Maximum Contamination Limit(MCL) <br /> B-Analyte detected In the associated Method Blank D-Surrogate Recovery Unreportable due to Dilution <br /> -Surrogate Recovery Outside Advisable QC Limits <br /> J F-sdmated Value between MDL and PQL 3116/00 2 45 57 PM <br /> I <br />