Laserfiche WebLink
i <br /> FORMER EXXON RS 7-3942: ITVIR DFSIGN <br /> Known and estimated parameters : <br /> • KH = 3.8 x 10-3 m/s From aquifer test <br /> • Kv = 3.8 x 10-4 m/s Assumed <br /> • v = 3 8 x 10'' m/s Darcy velocity from aquifer test <br /> • h = 0.01 Horizontal hydraulic gradient <br /> Set parameters : <br /> • <br /> H = 427 m Thickness of treatment zone <br /> • at = 2 m Length of top screen <br /> • ab = 122 m Length of bottom screen <br /> • Q = 2 m3/hr UVB well discharge <br /> Calculated parameters from numerical modeling: <br /> • Bt = 15.3 m Captured zone top width <br /> • Bb = 41. 1 m Captured zone bottom width <br /> • A = 147M2 Captured zone influx area <br /> 0 S = 13 8 m Stagnation point distance <br />