Laserfiche WebLink
*Cape Enwronmental Management lna. <br /> Health&Safely Plan <br />. 8.0 AIR MONITORIN <br /> Personnel and environmental exposure to airborne hazards will be monitored to ensure that <br /> exposures do not exceed acceptable limits Airborne contamination will be measured by a <br /> PID and/or Explosimeter. <br /> The data provided from these field monitoring activities will be used to determine levels of <br /> protection required and to help establish decontamination and disposal procedures. <br /> Periodic readings shall be taken with the PID to monitor volatile vapors During operations, <br /> PID readings will be taken at least every 30 minutes to determine the amount of volatile <br /> vapors in the breathing zone and 3 inches above the work area. Additionally, before <br /> handling the sample a PID reading will be taken and recorded. If the action levels listed in <br /> Table 1 indicate it is necessary, air monitoring will be conducted at least every 15 minutes. <br /> The Explosimeter will be continuously monitoring If PID readings approach action levels, <br /> results in working areas will be recorded at least every 30 minutes. <br /> All applicable monitoring or analytical instruments shall be calibrated daily. Calibration <br /> data, site reading, date, time, weather conditions, wind direction, and monitoring locations <br /> shall be recorded in Appendix D <br /> The PID and Explosimeter readings which require an action such as donning PPE or leaving <br /> the work area are summarized in Table 1. <br /> K064032 HSP 20 <br />