My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5606
>
2900 - Site Mitigation Program
>
PR0541401
>
ARCHIVED REPORTS_XR0008002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2020 2:57:42 PM
Creation date
4/14/2020 1:19:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008002
RECORD_ID
PR0541401
PE
2950
FACILITY_ID
FA0006046
FACILITY_NAME
UNION OIL STATION #5098
STREET_NUMBER
5606
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
02
SITE_LOCATION
5606 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. quarterly The manifold piping system and SVE wellhead configurations are not <br /> set up to measure vacuum in individual wells <br /> f Have air permeability tests been conducted on the extraction wells and air <br /> conductivity values calculated for those locations? This has not been <br /> completed <br /> g Have tracer tests been conducted to verify air flow paths and adequate <br /> travel times/velocities? (Normally done only where the site complexity <br /> justifies its use or where unusual vacuum/contaminant response to <br /> extraction is observed) This has not been completed <br /> h Has there been unexpected contamination found outside the capture zone <br /> or any indication of an unknown substance Groundwater contamination in <br /> the vicinity of groundwater monitoring wells MW-3 and MW-11 appears to be <br /> outside of the capture zone for SVE system <br /> i Are measurements of water table fluctuations made to determine the <br /> possible effects on the SVE system's performance? Yes Quarterly depth to <br /> groundwater measurements are collected from all groundwater wells The well <br /> screens for the SVE wells were installed at or above historical high groundwater <br /> elevations The well screens for SVE wells MW-23S, MW-25S, and MW-25D <br /> were submerged during ENSR's 4th Quarter 2004 vapor sampling event <br /> j Record the nameplate information from the vacuum blower, pumps, and <br /> other mechanical equipment for future reference Blower is a Sutorbilt model <br /> regenerative blower capable of 300-cubic feet per minute (cfm) The model <br /> numbers for the pumps and other mechanical equipment have not been <br /> recorded <br /> k Sketch a process flow diagram (PFD), including valves and instrument <br /> locations, on the back of this sheet or on a separate sheet See Attached <br /> I If modeling was performed, obtain a copy of the original SVE modeling <br /> done as part of the system design ENSR did not find any records to indicate <br /> that design modeling had been performed a part of the system design <br /> 5 Performance Analysis Calculations <br /> a Prepare flow rate versus time graphs for each extraction well Are the <br /> vapor extraction rates the same as those in the design specifications? <br /> Have the vapor extraction rates changed since the initial period of <br /> operation? Vapor flow rates for individual extraction wells does not exist since <br /> individual flprA, rate r nta fnr Pxtrartinn wpik rannnt ha arri rately mPaSured The <br /> design of the manifold piping system limits accurate measurement of individual <br /> flow rates in extraction wells when all wells are drawing vapor <br /> b Construct vacuum isopleth maps of the site Is the vacuum distribution <br /> consistent with that predicted during design? Does the vacuum <br /> distribution (in three dimensions) indicate captures of vapors and <br /> prevention of migration to receptors? ENSR has not constructed a vacuum <br /> Ol isopleth map for the extraction wells since individual flow rate data for extraction <br />
The URL can be used to link to this page
Your browser does not support the video tag.