Laserfiche WebLink
d DRAIN LINE WATER <br /> HORIZONTAL LENGTHS OF TRAP ARIAS (EXCEPT FOR WATERWATER SUPPLY AND DISTRIBUTION .. <br /> DIST <br /> FLOOR GRATE A4 CE <br /> CLOSETS AND SIMILAR FIXTURES)� _ <br /> MOUNT FLUSH � � TRAPAR'_�I TRAPARII< DISTA\CE MATERIAL SCHEDULE <br /> w/ FLOOR PIPE TRAP TO LENGTH PIPE TRAP TO LENGTH 1 . COPPER TUBING <br /> L VENT MAXIMUM <br /> DIAMETER DIAMETER VENT MAXIMUM . Cl. TYPE L MINIMUM WEIGHT <br /> vl � <br /> AIR GAP = 2 X •d° / ti; ' ��• M.I. IM MINIMUM b. TYPE M MAY BE USED, CONDENSATE, <br /> Maintain one-fourth ('.a} inch per foot slope (20.8 mmitu) AND PRESSURE RELIEF VALVES <br /> V a-°' 6 7 S 9 ' The developed length between the trap of a water closet or similar fixture C. COLOR CODE ON TUBING ARE AS <br /> LIFT OUT ALUMINUM <br /> W-. <br /> (measured from the top of the closet, flange to the inner edge of the vent) and it's FOLLOWS: TYPE K, GREEN; TYPE L, BLUE <br /> o° SEDIMENT BUCKET Q ` rn o vent shall not exceed six (6) feet (1,829 mm) <br /> _LA <br /> - _ TYPE M, RED. 019 STARBUCKS COFFEE COMPANY <br /> 30 (2 6 ) 32 mm 64 mm 762 mm <br /> WORKROAiA i 1,:�" 1�„ n „- �. as ©2 <br /> 2. VALVES UP TO AND INCLUDING 2 SHALL BE <br /> O 0- 9 VA I BACKBAR , 1 3„ ?” t3'-6"} 0 mm 76 mm 1,067 mm ,� <br /> STARBUCK <br /> E <br /> . ........ . . <br /> OF BRASS; LARGER THAN 2 CAN BE OF <br /> U - LI t }��- 2" . . ►" 60" (5%0") 50 mm 102 mm 1.524 mmBRASS OR CAST--IRON THE WORKING PARTS 2401 UTAH AVENUE SOUTH <br /> 3" 6" 72" 6"-0") 80 mm 152 ? SEATTLE, WASHINGTON98134 <br /> 4P1 n�� ( mm 1,8_9 mm TO BE OF NON-CORROSIVE MATERIAL <br /> HUB OUTLET — — — I 1""� . . (20fi} 3' 8-1575 <br /> 120" (10% 3. JOINTS AND CONNECTIONS, SOLDER SHALL NOT <br /> 1 I 41. 8" 100 mm 203 mm 3.048 mm <br /> HAVE A CONTENT OF LEAD THAT EXCEEDES V <br /> 13 FLOOR SINK DETAIL 2 3 � 1,u, 1�0' (10"- Exceeding 2 OF 1 %, SELECT SOLDER THAT IS SPECIFIC TARECONFDENTALANDSHA LREMAINTHEL <br /> e Exceeding 4 2, Diameter : ?> Dtatneter x,048 mm " SOLE PROPERTY OF STARBUCKS <br /> NTS 0 ) 100 mm FOR POTABLE WATER USE <br /> CORPORATION, WHICH IS THE OWNER OF THE <br /> COPYRIGHT IN THIS WORK. THEY SHALL NOT <br /> �` 4. HOT AND RETURN R N WATER PIPING TO B E ioi. BE REPRODUCED (IN WHOLE OR IN PART), <br /> cnr� <br /> FIBERGLASS INSULATED, MIN 1 /2" WALL THICKNESS SHARED WITH THIRD PARTIES OR USED IN ANY <br /> MANNER ON OTHER PROJECTS OR <br /> LINE OF WALL FIXTURE SCHEDULE, BAR AREA 5. GAS LINES TO BE BLACK STEEL PIPE SCH. 40 EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 6. CONDENSATE DRAINS TO BE TYPE M COPPER <br /> VENT TO ROOF{V.T.R.} 1 --1/2" MIN . PRIOR WRITTEN CONSENT OF STARBUCKSCORPORATION. THESE DRAWINGS AND <br /> SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> �--Si N K MIN CONNECTION SIZE FILTER SANITARY DRAINAGE DESIGN INTENT FOR A PROTOTYPICAL <br /> MARK DESCRIPTION ED NOTES 0 STARBUCKS STORE(WHICH IS SUBJECT To <br /> N WATER 1 . PIPING SHALL BE CAST IRON NO HUB CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> W V CW HW <br /> ACTUAL SITE CONDITIONS. NEITHER PARTY <br /> 1 MASTRENAS 112" 112" 0'-2" YES INDIRECT WASTE VENT, AND WASTE. I SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> 2. FITTINGS AND JOINTS SHALL BE OF CAST IRON THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br /> WRITTEN AGREEMENT 15 FULLY EXECUTED BY <br /> 2 SINK WI RINSER a' „ 2” 112" 112" 1-112" YES INDIRECT WASTE 3. MINIMUM 2% SLOPE FOR HORIZONTAL DRAINAGE i. BOTH PARTIES. <br /> 3 45 LB ICE CHEST 0'-1 - _ PIPING. — <br /> 112" Yz" 1" YES INDIRECT WASTE _STARBUCKS TEMPLATE VERSION 112019.05.31 <br /> 4. WASTE VENT SHALL RISE MINIMUM F" ABOVE THE - <br /> ---WALL CLEANOUT-2" 4 WORK SINK W/DRAIN 112" 1!2" 1-1 J2" NO INDIRECT WASTE <br /> FLOOD LEVEL RIM OF THE FIXTURE SERVED BEFORE LL ARCHITECT OF RECORD <br /> BOARD <br /> OFF--SETTING. THIS DRAWING IS A DESIGN <br /> DEVELOPMENT DOCUMENT. <br /> 5 90 LB ICE - - 112" - 1" YES SITE SPECIFIC MODIFICATIONS <br /> FL00 R WASTE LINE 2"(M I N) 6 COUNTER TOP RINSER 112" 112" 1-112" YES INDIRECT WASTE MADE UNDER THE RESPONSIBLE <br /> CHARGE OF THE ARCHITECT <br /> BREWER 112" YES Uj <br /> AND/OR ENGINEER-OF-RECORD <br /> WILL BE REQUIRED PRIOR TO <br /> 8 RINSE SINK 1-112" YES INDIRECT WASTE USING THIS DOCUMENT FOR <br /> BIDDING, PERMITTING, OR <br /> 9 HAND SINK <br /> j[11E2" 1/2" <br /> NO DIRECT WASTE <br /> z CONSTRUCTION. <br /> 14 HAND SINK PLUMBING 12 FIXTURE SCHEDULE, BACK BAR W <br /> NTS NTS N" PLUMBING <br /> DESIGN BUILD DATED / <br /> LEGEND I-Ic <br /> COLD WATER cV cV VENT 8'Y GUERRA BROS PLUIb7RI Go INCo <br /> — <br /> HOT WATER +—+�►,+ 5016 FORM DR,-SUITE D <br /> WALL CONST. HOT WATER RETURN NVR—runt--- WALL CONCORDGA 94520/ X256 <br /> I I SEE ARCH. DWGS, ,SIG RE <br /> �4� <br /> FILTERED COLD WATER F cV PCV-- <br /> MAY <br /> CV-----MAY EXTEND CLEANOUT INDIRECT WASTE ,V .�. - Yw <br /> AS WASTE 017 PLUG 1"AIRGAPATSINK <br /> FLOORSWKOR <br /> FLOOR DRAIN <br /> VENT COUNTERSUNK <br /> � <br /> SCREW SS WASTE <br /> cs� CLEANOUT <br /> a a <br /> C) TEE - POLISHED S.S. <br /> 5' D"'MAX TRAP ARM d <br /> �-- <br /> -1 ACCESS COVER I ' FOR 2"WASTE a r <br /> .. .� e <br /> U _ oLOtt3 I r1 YMORKROdRW <br /> a. © FL t <br /> _ 5 z w <br /> WASTE LINE w/ I �-'� L LI <br /> LENGTH TO SUIT L 4 WASTE LINE O <br /> � o 0 <br /> 1/8 BEND AT END — — — — '_� z O <br /> LL <br /> OF LINE CLEANOUT ' > <br /> FrI <br /> C = 4 FLOOR SINK DETAIL <br /> � Q <br /> W U <br /> WASTE LINE NTS Uj U j W <br /> CAFE NTS <br /> z <br /> r� <br /> O Q 10 11 Z W (' <br /> 13 WALL CLEANOUT DETAIL (�! <br /> 0. < W �. <br /> FIXTURE SCHEDULE, WORK AREA O LLL o Q <br /> O <br /> a C/� <br /> MARK DESCRIPTION MIN CONNECTION SIZE FIL TERE of of <br /> NOTES j a, <br /> W V CW HW IND W WATER <br /> cc <br /> STORE #: 47401 <br /> PROJECT#: 68888-00 <br /> N 10 HAND SINK 2" 1-112" 112" 112" DIRECT WASTE 2 <br /> d <br /> 2 COVER <br /> ISSUE DATE: 09/06119 <br /> PRODUCTION DESIGNER: <br /> 7 19 <br /> 3-COMP SINK 2" 2" Y2 Y" 2" INDIRECT WASTE <br /> a FIN. FLOOR W DESIGN MANAGER: NASIA KHAN <br /> 12 1000 LB ICE MAKER <br /> Y" - 1" YES <br /> WATER <br /> ICE MAKER,INDIRECT WASTE,FILTERED COLD FP <br /> CHECKED BY: SAROJA A <br /> f • ... <br /> ` - ' " •f ':. 1 WATER FILTRATION Revision Schedule <br /> .. -••• '.• 13 FROM OWNER <br /> LL SYSTEM 1" <br /> ADJUSTING`COLLA 14I MOP SINK FLORESTONE, MSR 24X24 2" 2" 1/2" 112" DIRECT WASTE Rev Date By Description <br /> CLEANOUT PLUG AND –RISER <br /> ���~ <br /> BODY. SEE SPECS. 15 WATER HEATER 220V/3P,9KW LT DUTY, 314" 1" 1" INDIRECT WASTE wrra■ _ <br /> 1/8 BEND FULL <br /> SIZE, 4" MAX. 16 FLOOR SINK. WATTS,FS-732•-22,WITH HALF GRATE 3" 2" - - - - DIRECT WASTE PLUMBING co <br /> I1 <br /> UJI <br /> (� INC. �'+ <br /> U-) PLUGIF END OF LINE SHEET TITLE: <br /> BY VUERI \]A BRl1(�S PLUMBING iPLUMBING, DETAILS <br /> FLOW � 5016 FORN I <br /> CD <br /> D R. SUITED SCALE:AS SHOWN <br /> 0) 9 FLOOR CLEANOUT DETAIL 13 FIXTURE SCHEDULE, WORK AREA SHEET NUMBER: <br /> CONCORD, CA 94520 / CL #802250 <br /> CD NTS <br /> P-01 <br />