My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1190
>
2200 - Hazardous Waste Program
>
PR0528517
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2020 4:14:01 PM
Creation date
4/16/2020 3:56:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528517
PE
2228
FACILITY_ID
FA0019193
FACILITY_NAME
SANBORN CHEVROLET PROLUBE SHOP
STREET_NUMBER
1190
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728012
CURRENT_STATUS
02
SITE_LOCATION
1190 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />CONTINUATION FORM <br />Page: 5 of 5 <br />OFFICIAL INSPECTION REPORT <br />Date: 09/16/13 <br />Facility Address: Sanborn Chevrolet Prolube 1190 S Cherokee Ln Lodi CA 95241 <br />Program: HW <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />tank inspections must be conducted and documented daily. (a) The owner or operator shall inspect, <br />where present, at least once each operating day: (1) overfill/spill control equipment (e.g., waste -feed <br />cutoff systems, bypass systems, and drainage systems) to ensure that it is in good working order; (2) the <br />aboveground portions of the tank system, if any, to detect corrosion or releases of waste; (3) data <br />gathered from monitoring equipment and leak -detection equipment, (e.g., pressure and temperature <br />gauges, monitoring wells) to ensure that the tank system is being operated according to its design; (4) <br />the construction materials and the area immediately surrounding containment structures (e.g., dikes) to <br />detect erosion or signs of releases of hazardous waste (e.g., wet spots, dead vegetation); and (5) for <br />uncovered tanks, the level of waste in the tank, to ensure compliance with section 66265.194(b)(3) .. . <br />(c) The owner or operator shall document in the operating record of the facility an inspection of those <br />items in subsection (a) and (b) of this section. The lube shop manager Anthony Morphis agreed to begin <br />documenting the hazardous waste tank inspections daily. Ensure that the required hazardous waste <br />tank inspections are conducted and documented daily. <br />133. This facility does not have a hazardous waste tank assessment for the used oil tank nor the used <br />coolant tank. Owners or operators of tank systems or components shall ensure that the foundation, <br />structural support, seams, connections, and pressure controls are adequately designed and that the tank <br />system has sufficient structural strength, compatibility with the waste(s) to be transferred, stored or <br />treated, and corrosion protection so that it will not collapse, rupture, or fail. The owner or operator shall <br />obtain a written assessment reviewed and certified by an independent, qualified, professional engineer, <br />registered in California in accordance with section 66270.11(d) attesting that the system has sufficient <br />structural integrity, is acceptable for the transferring, storing and treating of hazardous waste, and that <br />the tanks and containment system are suitably designed to achieve the requirements of this article. This <br />assessment shall be obtained prior to placing the tank system in service, and shall be kept on file at the <br />facility. Correct immediately by obtaining the required tank assessment for the used oil tank and the <br />used coolant tank per Title 22 hazardous waste regulations. Submit a copy to the EHD. <br />Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, by October 16, 2013. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TL)_!�kINSPECT)Gp AT ftNfJIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: _ <br />Aris Cacapit (209) 468-3453 <br />Riv By: <br />tj <br />Title: <br />l�gTt5aoa D.%zhur— <br />EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.