My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2200 - Hazardous Waste Program
>
PR0513919
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2020 12:20:04 PM
Creation date
4/27/2020 10:46:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513919
PE
2228
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
562
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. FILL RISER CONTAINMENT CTTMP TFQTiN!_ Page 2 <br />Facility is %lot C-ui With Fill Riser Containment Sumps- <br />- -- <br />Fill Riser Containment Sumps are Present. but Herr Nut Tested <br />Test Method Developed By: <br />Test Method Used: <br />Sump Manufacturer <br />Other tl�n�ifsl <br />Pressure <br />Other 6 ib,) <br />X Industry Standar! <br />Vacuum <br />Professional rngineer <br />X Hydrostatic <br />_ <br />F -qui la sed: RotaniCaldw Il Hydrostatic Sump rester E <br />W <br />iprnenl Resolution: 0.0020" <br />Weston ON <br />Reserve <br />SumpDiaateter <br />42~ <br />Diesel <br />42" <br />Sum <br />Hoot from Tank Top to Top of <br />H PI Penetration: <br />n a <br />tL'i <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />('orxlitiarn of sump prior to --- <br />testin <br />---- Clean <br />_ <br />__-Clem ----- --- <br />— <br />-- <br />------- <br />Portion of Sump Tested <br />Sump Matctial: <br />Fi Iris <br />Fiber2lass <br />Wait time between applying <br />prc%un lvacutan/wata and <br />starlingtest: _ <br />15 min <br />15 min <br />Test Start Ti mr <br />12:1 S <br />-- 12:1 S pm-- <br />-- -- -- --- <br />Initial Resdi ►. <br />I' Line <br />1" Line <br />Test End Time: <br />12:45 PM <br />12143 PM <br />Final Reath (R,): <br />I' I-ine <br />1" Line <br />Test Duration: <br />30 min <br />30 min <br />Change in Rad' (R •R : <br />0 <br />0 <br />Pass'Fail Threshold or Criteria: <br />PASS <br />No Lessor Loss of 0.0020" <br />or less in 30 minutes <br />Test Remk: <br />X Pass J7 Fail <br />X Pass 0 Fail <br />7 Pass U `ail <br />C; Past 0 Fail <br />Is there a sensor in the sump? <br />X Yes do <br />X Yes NO <br />x Yes No <br />Yes <br />No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />X Yes No NA <br />X Yes No NA <br />Yes tin %A <br />Yes Vo <br />NA <br />Was sensor removed fix testin ? <br />X Yes No NA <br />X Ycs Pio NA <br />Yes No NA <br />Yes Nb <br />NA <br />W as sensor pruperl) replaced and <br />verified functKmal atkr testing? <br />X Yrs Neo NA <br />X 1 r% Vo 1-� <br />Yrs %, o ti,� <br />Yes Swi <br />NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.