My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1990-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_1990-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:22:05 AM
Creation date
4/27/2020 12:23:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1990-2001
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_1990-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conversions 1 psi = 6895 Pa = 0.07031 kg/cm2 <br />1 bar =105 Pa =14.5 psi =1.02 kg/cm2 <br />1 MPa =106 Pa =145 psi =10.2 kg/cm2 <br />1 GPa =109 Pa =145,000 psi=10,200kg/cm2 <br />1 in= 25.4 mm <br />1 ft = 0.3048 m <br />1lb•in=0.113N•m <br />1 Btu • in/(h • ft2 • °F) = 0.1442 W/(m • K) <br />°C=5/9(°F —32) <br />Important notice This literature and the information and recommendations it contains are <br />based on data reasonably believed to be reliable. However, such factors as <br />variations in environment, application or installation, changes in operating <br />procedures, or extrapolation of data may cause different results. Ameron <br />makes no representation or warranty, express or implied, including warran- <br />ties of merchantability or fitness for purpose, as to the accuracy, adequacy <br />or completeness of the recommendations or information contained herein. <br />Ameron assumes no liability whatsoever in connection with this literature <br />or the information or recommendations it contains. <br />Written comments regarding this document are invited. Please write <br />Engineering Manager, Ameron Fiberglass Pipe Division. <br />.11111e1'Vllm <br />Fiberglass Pipe Division <br />Fiberglass Pipe Division <br />Ameron (Pte) Ltd. <br />Post Office Box 801148 <br />J.F. Kennedylaan 7 <br />No. 7A, Tuas Avenue 3 <br />Houston, Texas 77280 <br />4191 MZ Geldermalsen <br />Singapore 2263 <br />Phone (713) 690-7777 <br />The Netherlands <br />Phone 862-1301 <br />Telex 293096 AMERON FPD <br />Phone 03455-73341 <br />Telex 38960 AMERON RS <br />FAX (713) 690-2842 <br />Telex 40257 BONDS NL <br />FAX 862-1302 <br />Composition <br />FAX 03455-75254 <br />Manufacturing plants: Burkburnett, Texas, Spartanburg, South Carolina, Geldermalsen, The Netherlands <br />and Singapore. Bondstrand pipe is also manufactured in Japan and Saudi Arabia. <br />© 1985 Ameron FP265C (R7/89) supersedes FP265B (R8188) Printed in U.S.A. 51A <br />• • <br />Dualoy 3000/L <br />Fiberglass Pipe and Fittings <br />underground piping for petroleum products, <br />alcohols and alcohol -gasoline mixtures <br />Uses and applications <br />Service station product, vent and vapor recovery piping <br />Bulk plant terminals <br />Airports, marinas and marine terminals <br />Performance <br />Operating pressures to 300 psig. <br />Continuous temperatures to 150°F (66°C) maximum. <br />• • Listing <br />Dualoy 3000/L pipe system is listed with Underwriters' Laboratories, Inc., File <br />L/ <br />MH 9162 for underground piping for petroleum products, alcohols and alcohol - <br />gasoline mixtures. It is also listed with Underwriters' Laboratories of Canada, <br />tLUNDERWRITERS' <br />LABORATORIES, �,.� <br />INC. <br />File CMH715 for use with petroleum products. <br />Composition <br />Pipe <br />Filament -wound fiberglass reinforced epoxy pipe with integral epoxy liner and <br />exterior coating. When classified in accordance with ASTM D2310 and ASTM <br />D2996, the pipe meets the following cell limits: RTRP-11CF 5430. <br />Fittings <br />Compression -molded and filament -wound fiberglass reinforced epoxy <br />Adhesives <br />C20HT two-part epoxy (petroleum products only) <br />RP -48A two-part epoxy (all services) <br />Joining system <br />Bell and spigot tapered adhesive bonded joint. <br />Tapered spigot x tapered spigot <br />Pipe lengths <br />Standard 20 ft random lengths (17 to 21 ft). <br />Longer lengths available on request. <br />Fittings <br />Elbows' <br />90° 45° <br />Tees' Threaded adapters' End caps' <br />Reducer bushings Sleeve couplings Nipples Flanges <br />• • <br />Other fittings available without UL listing. <br />Molded fittings must be identified as being intended for alcohol service. Materials used to mold <br />alcohol -qualified fittings are different than those used to mold fittings for petroleum products only. <br />
The URL can be used to link to this page
Your browser does not support the video tag.