Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Quik Stop #132 <br />Site Address: 3555 W. Hammer Ln. <br />Facility Contact Person: Michael Karvelot <br />Make/Model of Monitoring System: Veeder- Root TLS 350 <br />B. Inventory of Equipment Tested/Certified <br />Cherk the annrnnriate hnses to indirate snerifir enninment imnertedAervired- <br />Bldg. No.: <br />City: Stockton Zip: 95219 <br />Contact Phone No.: 510 ) 657-8500 <br />Date of Testing/Servicing: 6 /20 /05 <br />Tank ID: 87 <br />Tank ID: 89 <br />N In -Tank Gauging Probe. <br />Model: Mag Probe <br />■ In -Tank Gauging Probe. <br />Model: Mag Probe <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />■ Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />N Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />■ Piping Sump / Trench Sensor(s). <br />Model: 0794380-208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: FE Petro STP -MLD <br />■ Mechanical Line Leak Detector. <br />Model: FE Petro STP -MLD <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: oPW 61 So-EVR <br />■ Tank Overfill / High -Level Sensor. <br />Model: oPW 61 So-EVR <br />❑ Other(specify equipment a and model in Section E on P e 2). <br />❑ Other (specify equipment a and model in Section E on P e 2). <br />Tank ID: 91 <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: Mag Probe <br />❑ In -Tank Gauging Probe. <br />Model: <br />Annular Space or Vault Sensor. <br />Model: 0794390-409 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: 0794380-zo8 <br />❑Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />■ Mechanical Line Leak Detector. <br />Model: FE Petro STP -MLD <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: OPW 61So-EVR <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment a and model in Section E on Page 2). <br />❑ Other (speciEy a ui ment type and model in Section E on P e 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 5-6 <br />Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />® Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />Shear Valve(s). <br />E Shear Valve(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 7-8 <br />Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />® Dispenser Containment Sensor(s). <br />Model: 0794380-208 <br />Shear Valve(s). <br />Shear Valve(s). <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s). <br />❑Dis enser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up ❑Q la history report <br />Technician Name (print): Phillip Klingman Signature: <br />Certification No.: 006-05-0809 <br />License. No.: 617238 <br />Testing Company Name: Walton Engineering, Inc. Phone No.:l 916 ) 373-1152 <br />Site Address: 3900 Commerce Drive, West Sacramento, CA 95691 Date of Testing/Servicing: 6 / 20 /05 <br />UN -036 - 1/4 Page 1 of 3 Rev. 06/04/01 <br />COPA: San Joaquin County Env. Health <br />INSPECTOR: Michelle Le <br />ALTON <br />"ENGINEERING, I C. <br />www.unidocs.org <br />