My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_2001-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:28:12 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2008
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_2001-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method By: <br />Test Method Uses: <br />Measuring Equipment Used: <br />Manufacturer ♦ Industry Standard <br />Pressure : • Vacuum <br />Level Change Indicator <br />Professional Engr. Other (see below) <br />i Hydrostatic Other (see below) <br />(Caldwell System 2001 ! Walton Engineering) <br />Description <br />Disp # 1/2 <br />Disp # 3/4 <br />Disp # 5/6 <br />Disp # 7/8 <br />Entire <br />UDC manufacturer <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />Was sensor properly replaced after testing? <br />Yes <br />UDC material <br />FRP <br />FRP <br />FRP <br />FRP <br />UDC depth (inches) <br />30" <br />30" <br />30" <br />30" <br />Sensor <br />Depth of water level from UDC bottom (in.) <br />Height from UDC bottom to highest <br />piping penetration <br />11" <br />8" <br />12" <br />10" <br />11:30 AM <br />11:33 AM <br />Height from UDC bottom to lowest <br />electrical penetration <br />4" <br />Bottom <br />4" <br />4" <br />12:07 PM <br />12:10 PM <br />Type <br />0:30 <br />0:30 <br />0:30 <br />0:30 <br />Change in water level (t 0.000 inches) <br />0.000 <br />0.000 <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches 134 Hr.) <br />0.005 <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />Condition of UDC prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />of shut -down resent <br />Sensor <br />Sensor <br />Sensor <br />Sensor <br />Condition of UDC prior to testing <br />Comments: <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Wait time for water level to stabilize (hrmin) <br />0:04 <br />0:03 <br />0:06 <br />0:07 <br />Depth of water level from UDC bottom (in.) <br />13" <br />10" <br />14" <br />12" <br />Test start time <br />11:30 AM <br />11:33 AM <br />11:37 AM <br />11:40 AM <br />Test end time <br />12:00 PM <br />12:03 PM <br />12:07 PM <br />12:10 PM <br />Test duration (hr:min) <br />0:30 <br />0:30 <br />0:30 <br />0:30 <br />Change in water level (t 0.000 inches) <br />0.000 <br />0.000 <br />0.000 <br />0.000 <br />Pass/Fail threshold (0.005 inches 134 Hr.) <br />0.005 <br />0.005 <br />0.005 <br />0.005 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />PASS <br />2003 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.