My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2001-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_2001-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:28:12 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2008
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_2001-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT%3ING SYSTEM CERTI ATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC <br /> CERTIFICATION /TEST DATE: June 19, 2008 <br /> Al. FACILITY A2. OWNER <br /> Name Quik Stop Market#132 Name Quik Stop Markets, Inc. <br /> Address 3555 W.Hammer Lane,Stockton,CA 95219 Address 4567 Enterprise Street,Fremont,CA 94538 <br /> Phone# 510-657-8500 Phone# 510-657-8500 <br /> Contact Michael Karvelot Contact Michael Karvelot <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified June 12,2008 Lic# 617238 A,B,Haz <br /> Inspector Garrett Backus Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> 131: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-89 <br /> ■ In-Tank Gauging Probe Model: 0846390-107 ■ In-Tank Gauging Probe Model: 0846390-107 <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ■ Annular Space or Vault Sensor Model: 0794390-409 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: Vaporless 99LD-2000 ■ Mechanical Line Leak Detector Model: Vaporless 99LD-2000 <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ■ Tank Overfill/High-Level Sensor Model: OPW61SO ■ Tank Overfill/High-Level Sensor Model: OPW61SO <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Gasoline-91 Tank#4 (Product): _ <br /> ■ In-Tank Gauging Probe Model: 0846390-107 ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: FE Petro STP-MLD ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ■ Tank Overfill/High-Level Sensor Model: OPW61SO ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> B2: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5-6 Dispenser#: 7=8 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspectediserviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> WALTON <br /> Signature: _ ENGINEERING,INC. <br /> Technician/Cert M Bruce N.Stewart/A31131 5249892-UT Date: June 19,2008 <br /> ©2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.