Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fan: (209) 468-3433 Web: www.sjgov.org/ehd <br />....... ..:.. <br />1 17, 2017 <br />3555 W HAMMER LN, STOCKTON, CA 95209 1 10180893 <br />Inspection Contact: Title: Phone. <br />Ruse Kaur Manager (209) 951-3195 <br />Inspection Type: Program: <br />ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br />Consent For: I Consent Given By: <br />® Inspection ® Photos ® Samples I Ruse Kaur, Manager <br />Curtis Carpernter 06/06/2018 Curtis Carpenter 02/05/2019 <br />Service Technician Manufacturer's Training: <br />VMI, 02/24/19; Veeder Root, 12/29/18 <br />V = Violation R =Repeat violation COS = Corrected on site during inspection I <br />101 <br />1 HSC 25284 <br />No permit to operate <br />❑ V <br />❑ R <br />❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R <br />❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V <br />❑ R <br />❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />❑ V <br />❑ R <br />❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V <br />❑ R <br />❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V <br />❑ R <br />❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />❑ V <br />❑ R <br />❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V <br />❑ R <br />❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />❑ R <br />❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V <br />❑ R <br />❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R <br />❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V <br />❑ R <br />❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R <br />❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R <br />❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V <br />❑ R <br />❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V <br />❑ R <br />❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V <br />❑ R <br />❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V <br />❑ R <br />❑ COS <br />122 <br />CCR 26310) <br />Failure to submit UST system component statement of compatibility for substance stored <br />❑ V <br />❑ R <br />❑ COS <br />201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■ V ❑ R ❑ COS <br />202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ❑ V ❑ R ❑ COS <br />203 CCR 2712(b) Failed to maintain records of monitoring, repair, lining, and upgrades on site ❑ V ❑ R ❑ COS <br />FA0002232 PR0231130 SCO01 04/17/2017 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 4 Underground Storage Tank Program OIR <br />