My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3555
>
2300 - Underground Storage Tank Program
>
PR0231130
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 10:37:32 AM
Creation date
4/27/2020 12:23:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231130
PE
2361
FACILITY_ID
FA0002232
FACILITY_NAME
QUIK STOP MARKET #3132*
STREET_NUMBER
3555
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
071-180-20
CURRENT_STATUS
01
SITE_LOCATION
3555 W HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231130_3555 W HAMMER_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
479
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CJ 2014 Walton Engineering, Inc. <br />SY EM SET-UP REPOR <br />age 2) <br />T 3:Premium_Unlead LIQUID SENSOR SETUP - — - <br />PRODUCT CODE B - - - - - - - - - - - - ISD SITE ALARMS SMARTSENSOR SETUP <br />THERMAL COEFF :.000700 ISD GROSS PRES FAIL - - - - - - - - - - - - <br />TANK DIAMETER 92.00 L 1:UNL SUMP ISD DEGRD PRES FAIL <br />TANK PROFILE 4 PTS TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL s 1:DISP 1-2 AFM <br />FULL VOL 7841 CATEGORY : STP SUMP ISD VF PRES FAIL CATEGORY AIR FLOW METER <br />69.0 INCH VOL 6554 ISD VP STATUS FAIL <br />46.0 INCH VOL 4099 s 2:DISP 3-4 AFM <br />23.0 INCH VOL 1585 L 2:PLUS SUMP ISD HOSE ALARMS CATEGORY AIR FLOW METER <br />TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL <br />CATEGORY : STP SUMP s 3:DISP 5-6 AFM <br />FLOAT SIZE: 4.0 IN. R 2:PLUS UNL CATEGORY AIR FLOW METER <br />TYPE: <br />WATER WARNING 3.0 L 3:PRE SUMP STANDARD s 4:DISF 7-8 AFM <br />HIGH WATER LIMIT: 5.0 TRI-STATE (SINGLE FLOAT) NORMALLY CLOSED CATEGORY AIR FLOW METER <br />CATEGORY : STP SUMP <br />MAX OR LABEL VOL: 7841 TANK tt: 2 s 5:DISP 3-4 VAP PRESS <br />OVERFILL LIMIT 900/0 CATEGORY VAPOR PRESSURE <br />7095%56 L ANL <br />HIGH PRODUCT TRI-SUNLTATE IN -TANK ALARMS s 6:VENT CANISTES <br />TRI-STATE (SINGLE FLOAT) <br />449 T 2:PROBE OUT CATEGORY VAPOR VALVE <br />7449 CATEGORY ANNULAR SPACE <br />DELIVERY LIMIT 20% <br />1568 LIQUID SENSOR ALMS <br />L 2:FUEL ALARM CATEGORY ATM P SENSOR <br />LOW PRODUCT 800 L 5:PLUS ANL L 7:FUEL ALARM <br />LEAK ALARM LIMIT: 99 TRI-STATE (SINGLE FLOAT) L 8:FUEL ALARM <br />SUDDEN LOSS LIMIT: 99 CATEGORY : ANNULAR SPACE L 9:FUEL ALARM _ <br />TANK TILT 0.00 L10:FUEL ALARM EVR/ISD SETUP <br />PROBE OFFSET 0.00 L 2:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 6:PRE ANL L 8:SENSOR OUT ALARM <br />SIPHON MANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) L 9:SENSOR OUT ALARM EVR TYPE: BALANCE <br />TO: NONE CATEGORY : ANNULAR SPACE L10:SENSOR OUT ALARM <br />LINE MANIFOLDED TANKS L 2:SHORT ALARM BALANCE NOZZLE TYPE <br />TO: NONE L 7:SHORT ALARM UST <br />L 8:SHORT ALARM <br />L 7:DISP 1-2 L 9:SHORT ALARM VAPOR PROCESSOR TYPE <br />LEAK. MIN PERIODIC: 0% TRI-STATE (SINGLE FLOAT) L10:SHORT ALARM VEEDER-ROOT POLISHER <br />0 CATEGORY : DISPENSER PAN <br />PERIODIC TEST TYPE ISD SITE ALARMS <br />STANDARD ISD GROSS PRES FAIL ANALYSIS TIMES <br />ISD DEGRD PRES FAIL TIME: 10:00 AM <br />PERIODIC TEST FAIL L 8:DISP 3-4 ISD VAPOR LEAK FAIL DELAY MINUTES: 1 <br />ALARM DISABLED TRI-STATE (SINGLE FLOAT) ISD VP PRES FAIL <br />CATEGORY : DISPENSER FAN ISD VP STATUS FAIL <br />GROSS TEST FAIL ACCEPT HIGH ORVR: <br />ALARM DISABLED IADLHOSE ACOLLMS DISABLED <br />ECT FAIL <br />L:FLOPER <br />TEST AVERAGING: OFF L 9:DISP 5-6 ISD HOSE TABLE <br />TRI-STATE (SINGLE FLOAT) R 3:FRE UNL ID FP FL HL AA RR <br />TANK TEST NOTIFY: OFF CATEGORY : DISPENSER PAN TYPE. ------------------------ <br />STANDARD 01 01 01 02 01 UU <br />TNK TST SIPHON BREAK:OFF NORMALLY CLOSED 02 02 02 02 01 UU <br />TANK : 3 03 03 03 02 02 UU <br />DELIVERY DELAY 2 MIN L10:DISF 7-8 04 04 04 02 02 UU <br />PUMP THRESHOLD 10.00% TRI-STATE (SINGLE FLOAT) 05 05 05 02 03 UU <br />CATEGORY DISPENSER PAN 06 06 06 02 03 UU <br />IN -TANK ALARMS 07 07 07 02 04 UU <br />T 3:PROBE OUT 08 08 08 02 04 UU <br />LEAK TEST METHOD OUTPUT RELAY SETUP LIQUID SENSOR ALMS <br />L 3:FUEL ALARM ISD AIRFLOW METER MAP <br />TEST ON DATE : ALL TANK L 7:FUEL ALARM ID <br />SERIAL NUM LABEL <br />DEC 22, 1999 R 1:REG UNL L 8:FUEL ALARM ------------------------ <br />START TIME : DISABLED TYPE: L 9:FUEL ALARM 1 31027 DISP 1-2 A <br />TEST RATE :0.20 GAL/HR STANDARD L10:FUEL ALARM 2 20123 DISP 3-4 A <br />DURATION 2 HOURS NORMALLY CLOSED L 3:SENSOR OUT ALARM 3 24977 DISF 5-6 A <br />L 7:SENSOR OUT ALARM 4 31038 DISP 7-8 A <br />TST EARLY STOP:DISABLED TANK 0: 1 L B:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />LEAK TEST REPORT FORMAT L10:SENSOR OUT ALARM ISD FUEL GRADE HOSE MAP <br />NORMAL LIQUID SENSOR ALMS L 3:SHORT ALARM <br />L 1:FUEL ALARM L 7:SHORT ALARM FP MHH MHH MHH MHH AA <br />L 7:FUEL ALARM L 8:SHORT ALARM ------------------------ <br />L B:FUEL ALARM L 9:SHORT ALARM 01 201 101 001 U U 1 <br />L 9:FUEL ALARM L10:SHORT ALARM 02 202 102 002 U U 1 <br />LIO:FUEL ALARM 03 203 103 003 U U 2 <br />L i:SENSOR OUT ALARM ISD SITE ALARMS 04 204 104 004 U U 2 <br />L 7:SENSOR OUT ALARM ISD GROSS PRES FAIL 05 205 105 005 U U 3 <br />L B:SENSOR OUT ALARM ISD DEGRD FRES FAIL 06 206 106 006 U U 3 <br />L 9:SENSOR OUT ALARM ISD VAPOR LEAK FAIL 07 207 107 007 U U 4 <br />L10:SENSOR OUT ALARM ISD VP PRES FAIL 08 208 108 008 U U 4 <br />L 1:SHORT ALARM ISD VP STATUS FAIL <br />L 8:SHORT ALARM ISD HOSE ALARMS <br />L 7:SHORT ALARM RECEIVED <br />,� <br />L 9:SHORT ALARM ALL:FLOW COLLECT FAIL V <br />L10:S11ORT ALARM <br />MAY 01 2014 <br />ENVIRONMENTAL HEALTH <br />PERMIT/SERVICES <br />CJ 2014 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.