My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2417
>
2200 - Hazardous Waste Program
>
PR0513704
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2024 2:59:25 PM
Creation date
4/27/2020 12:24:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513704
PE
2220
FACILITY_ID
FA0005570
FACILITY_NAME
Superior Roadside And Towing Inc
STREET_NUMBER
2417
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95205
APN
11709007
CURRENT_STATUS
01
SITE_LOCATION
2417 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2220_PR0513704_2417 WEST_.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sd&quin County Environmental He gWpartment <br /> Continued HAZARDOUS WASTE GENERATOR PROGRAM INS TION REPORT <br /> Inspect n Dqte: <br /> I <br /> Facility Address: 2,cj�1-7 L- IVIOLATIONS <br /> I a IV I RV Code Section <br /> 50 25160(d)HSC Transported hazardous waste without a manifest. <br /> 51 25163(a)HSC Transported hazardous waste or transferred HW to a transporter without valid registration. <br /> o g <br /> 52 25160.2(cX2)HSC Offered ineligible waste streams to be transported <br /> usinconsolidated manifest. <br /> Offered <br /> a53 25160.2(bX4)HSC Consolidated manifest receipts failed to contain complete information. <br /> 0Z 54 25250.23 HSC Transported used oil and not registered as a hazardous waste hauler. <br /> 55 66263.17(a)CCR Transported hazardous waste without receiving ID Number and registration cert from DTSC. <br /> 56 66263.23(b)CCR Delivered hazardous waste to an unauthorized facility. <br /> 57 66265.17 CCR Failed to manage incompatible waste in containers properly. <br /> Ij 58 66265.199 CCR Failed to manage incompatible waste in tanks properly. <br /> 59 <br /> Contaminated used oil with other hazardous waste. <br /> 1 25250.7 HSC <br /> 60 66266.81(b)CCR Damaged lead acid batteries not properly managed and labeled. <br /> 61 66265.191(a)CCR Failed to determine if HW tank is leaking or unfit. <br /> 62- 66265.191(b)CCR HW tank assessment not sufficient. <br /> 63 66265.191(4)CCR If HW tank found leaking or unfit failed to comply with 66265.196. <br /> Z 64 66265.192 CCR Failed to retain on-site required certification for HW tanks. <br /> 65 66265.193 CCR Failed to provide secondary containment for HW tank. <br /> LU Placed hazardous waste or reagents in tank system that caused the tank,containment <br /> 66 66265.194(a)CCR <br /> U) system or ancilla!y equipment to leak,corrode, rupture,or fail. <br /> 3: 67 66265.194(b)CCR Failed to use controls and practices to prevent spillage and overflows from tank system. <br /> U) 68 66265.194(b 3)CCR Failed to prevent overtopping from HW tank. <br /> 0 69 66265.195(a)CCR Failed to conduct daily inspections of HW tank. <br /> it 70 66265.195(b)CCR Failed to inspect HW tank cathodic protection system. <br /> 71 66265.196 CCR Failed to immediately remove tank/secondary containment system that had leaked or spilled. <br /> x 72 66265.197 CCR Tank closure,failed to remove/decon all waste and manage them as HW. <br /> 73 66265.198(a)/(b)CCR Failed to manage ignitable or reactive waste properly. <br /> 74 66265.199(a)/(b)CCR Failed to manage incompatible wastes properly. <br /> 75 66273.32(a)CCR Failed to notify the EPA RA to obtain an EPA ID#prior to accumulating>50004 of UW. <br /> 76 66273.32(c)CCR Cathode Ray Tube(CRT)handler failed to notify DTSC 30 days prior to accepting offsite UW. <br /> 77 66273.33(a)CCR Failed to store UW batteries in a closed container and in a manner that prevents breakage <br /> and release to the environment. <br /> Failed to:(1)store UW lamps in a closed container and in a manner that prevents breakage <br /> 78 66273.33(b)CCR and release to the environment,or(2)immediately clean and containerize any broken lamps <br /> or releases to the environment. <br /> LU Failed to store mercury containing UW in closed or airtight containers in a manner that <br /> l-- <br /> 79 66273.33(c)CCR prevents breakage and release to the environment,or failed to immediately clean and <br /> containerize any broken mercury containing UW or release to the environment. se <br /> Failed to:(1)store a UW electronic device in a manner that prevents breakage and releato <br /> vai 80 66273.33.5(a)(1)(B)CCR the environment,or(2)immediately clean and containerize any broken electronic device or <br /> release to the environment. <br /> LU <br /> > Failed to:(1)contain a CRT in a manner that prevents breakage and release to the <br /> Z 81 66273.33 5(b)(1)(B)CCR environment,or(2)immediately clean and containerize any broken CRT or release to the <br /> environment. <br /> 82 66273.34 CCR Failed to label universal waste to identify type of universal waste. (a)Batteries,(b)Mercury <br /> containing equipment,(c)Lamps,(d)Electronic devices,(e)CRTs,(f)CRT glass <br /> 83 66273.35 CCR (a)Stored UW onsite for more than 1 year,or(b)was unable to demonstrate the length of <br /> time the UW has been accumulated from the date it became a waste or was received. <br /> 84 66273.36 CCR Training records for UW management and emergency response procedures incomplete. <br /> 85 66273.39 CCR Failed to keep records of each shipment of universal waste according to this section. <br /> 86 66262.34(d)CCR& Stored hazardous waste onsite greater than 180 days. <br /> 25123.3(h)(1)HSC <br /> 87 66262.34(d Accumulated more than 6,000 kg of HW onsite at one time. <br /> Modified emergency coordinator information lacking or insufficient[as referenced by CFR <br /> CIR <br /> CR <br /> )CCR& <br /> I HSC <br /> X1)CCR <br /> 88 66262.34(dX2)CCR 262.34(d)and CFR(e)&ffl] <br /> An empty HW or Haz Mat container(larger than 5 gallons)was not marked with the date it <br /> 89 66261.7(o CCR <br /> LU was emptied/not managed within one year of being emptied. <br /> x <br /> 90 2R2-171 HSCLiquid latex paint was disposed of,or attempted to be dispo d of,to land or water. <br /> 91 See attached.Continuation-Official Inspection Report"for violation(s)not listed above. <br /> UIC I Septic System:_Serves>20 persons/day _Receives other sanitary waste _Dry wells/French Drains Onsite <br /> EHD Inspector. Title: <br /> AA. krce�' <br /> EHD 22-02-004 Rev 3109 600 EAST MAIN STREET,STOCKTON,CA 95202(209)468-3420 Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.