Laserfiche WebLink
mmo Hpprovea wive—rneaiy r-nase n cvr..oystem— vr%-Lu i-H tyuu r4ozziel rage o <br /> Healy 900 Series Nozzle <br /> 1.0 Field Repair Instructions <br /> 1.1 Healy Part No. 6395B Mini-Boot Replacement for 900 Series Nozzles <br /> 1.1.1 To remove the old Mini-Boot, unscrew the Mini-Boot Clamp (see Sections 1.7 <br /> & 1.8, Item 2) and remove. <br /> 1.1.2 Grip the Mini-Boot and rotate back and fourth a maximum of 50 degrees in <br /> each direction while gently pulling to separate the Mini-Boot from the nozzle. <br /> Installing the new Mini-Boot <br /> NOTE: Heating the Mini-Boot in water softens the material, making it easier to install. <br /> 1.1.3 Use a push rod checking tool (.050 hex wrench or 1/16" drill bit) to verify that a <br /> clear hole condition exists in the push rod hole of the spout body before <br /> proceeding. <br /> 1.1.4 Align the push rod extending from the nozzle end of the boot with the 1/16" <br /> hole in the spout body while also aligning the 3/16" hole in the mini-boot with <br /> the 3/16" pin on the spout body (See photos below). <br /> 1.1.5 Start the push rod into the 1 /16" hole and slide the boot axially into <br /> engagement with the spout body and the boot location pin while limiting <br /> angular rotation of the boot to 50 degrees in each direction to avoid bending <br /> the push rod. <br /> 1.1.6 Install the mini-boot clamp and tighten securely. Verify that the "HEALY" logo <br /> on the Mini-Boot is aligned with the top center of the nozzle. <br /> i� r <br /> \. <br /> pzr <br /> ,y4 <br /> 1.1.7 Verify that the nozzle will not dispense fuel when the dispenser is authorized <br /> (ready to dispense fuel) and the boot is in a free state by holding the nozzle <br /> into an approved container (do not compress the mini-boot in any manner) and <br /> actuate the nozzle. No fuel should dispense. If fuel does not dispense, <br /> Healy Systems, Inc. Website: http://www.healysystems.com <br /> 18 Hampshire Drive Email: sales@healysystems.com <br /> Hudson, New Hampshire 03051 USA Telephone 603.882.2472 <br /> ARB Approved Installation, Operation and Maintenance Manual (April 8, 2005) Fax 603.882.5189 <br /> Healy Systems, Inc. —the innovative leader of Stage 11 vapor recovery equipment <br />