Laserfiche WebLink
Kennedy/Jenks Consultants <br /> Table 5: Measures for Level C Decontamination <br /> Station Description <br /> 1 Equipment Drop <br /> Deposit equipment used onsite (tools, sampling devices and containers, monitoring <br /> instruments, radios, clipboards, etc.)on plastic drop cloths. Segregation at the drop <br /> reduces the probability of cross contamination. During hot weather operations, a cool <br /> down station may be set up within this area. <br /> 2 Outer Garment, Boots, and Gloves Wash and Rinse <br /> Scrub outer boots, outer gloves and splash suit with decon solution or detergent water. <br /> Rinse off using copious amounts of water. <br /> 3 Outer Boot and Glove Removal <br /> Remove outer boots and gloves. Deposit in container with plastic liner. <br /> 4 Canister or Mask Change <br /> If worker leaves Exclusion Zone to change canister(or mask), this is the last step in the <br /> decontamination procedure.Worker's canister is exchanged, new outer gloves and boot <br /> covers donned,joints taped, and worker returns to duty. <br /> 5 Boot, Gloves and Outer Garment Removal <br /> Boots, chemical-resistant splash suit, inner gloves removed and deposited in separate <br /> containers lined with plastic. <br /> 6 Face Piece Removal <br /> Facepiece is removed.Avoid touching face with fingers. Facepiece is deposited on <br /> plastic sheet. <br /> 7 Field Wash <br /> Hands and face are thoroughly washed. Shower as soon as possible. <br /> Site Health and Safety Plan Page 1 of 1 <br /> Former Tracy Railyard, Tracy, California <br /> g:Gs-ToLq)W inl obW510565777.03_uprr101reponslwork planVi finallappendioestappc_Aasplappc_lexl.doc <br />