My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
2701
>
3500 - Local Oversight Program
>
PR0545618
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:57:04 PM
Creation date
4/27/2020 4:41:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0545618
PE
3528
FACILITY_ID
FA0003568
FACILITY_NAME
AMERICAN TRANSFER
STREET_NUMBER
2701
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95205
APN
17911008
CURRENT_STATUS
02
SITE_LOCATION
2701 S HWY 99
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
cIlei <br /> 'J7 <br /> SAN JOACUIN COUP :'UBLIC HEALTH SERVICES/ENVIRONMENTAL HEAL "",vISION <br /> WORKSHEET FOR SITE CLOSURE EVALUATION DATE _. <br /> SWEEPS CODE �3 <br /> NAME OF FACILITY <br /> '' / C? G TANK ID # - / <br /> / ADDRESS J ilrcl <br /> TANK SIZE tc, wd FUEL TYPE r <br /> II. GENERAL SITE HISTORY *rr► <br /> Is permit current? Yes No Permit # - Facility Status Code / Doc.Soil/GW Cont Yes No <br /> Number of Tanks et facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed?nes <br /> No BTXE 7PH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastrophic long-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year ; Average Annual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & Type Irr Dom Pub S Score S Score S Score <br /> Distance to Well(s) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) b None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration C°'—` 1 None Unknown 5 Present <br /> of leachate (i.e., septic systems, water wells, ponds Lc) <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxx None one one <br /> COLUMN TOTALS»>TOTAL POINTS , + g ID = 3 Q <br /> Sample Result: :a T X OR RANGE OF TOTAL POINTS 49 pts or more 41 - 48 p 40 pts or less <br /> 8 T X E B T J.X <br /> (J MAXIMiJM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. NA\3 <br /> S le esult: �QGASOLINE 1000 100 10 <br /> K� ��� 0 PN MAXIMUM ALLOWABLE TPH LEVELS (PPM) DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the lea potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes Na <br /> 2. Recommend Site Closure Yes No *If Yes, Refer to Site Mitigation for Evaluation <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF - <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT A5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.