My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005798
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
935
>
3500 - Local Oversight Program
>
PR0545617
>
ARCHIVED REPORTS_XR0005798
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2020 2:00:56 PM
Creation date
4/28/2020 1:10:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005798
RECORD_ID
PR0545617
PE
3528
FACILITY_ID
FA0005557
FACILITY_NAME
RIPON FARM SERVICE
STREET_NUMBER
935
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102007/2011
CURRENT_STATUS
02
SITE_LOCATION
935 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Site Background Information - Ripon Farm Service <br /> . Page 7 of 9 <br /> Elevated concentrations of dissolved oxygen were periodically detected in monitoring wells used as <br /> ' observation wells within and outside the IAS network on the site The highest dissolved oxygen <br /> value measured in well MW-1 was at 12 1%, and in well MW-2 at 20 8% Generally, dissolved <br /> oxygen concentrations measured in the wells remained stable at, or sporadically increased above, <br /> ' pre-remedial levels Sparging rates were measured at approximately 6 cfin during each monitoring <br /> event A pressure of approximately 10 psi was maintained for the air sparging flow rate <br /> ' The estimated mass of hydrocarbons removed was based on laboratory analysis of soil-vapor <br /> samples The mass of extracted hydrocarbons was calculated for each time period using average <br /> hydrocarbon concentrations of influent soil-vapor sample data and average air flow rates A total of <br /> ' 2,122 45 kg(4,229 12 lbs), or a volume of 748 5 gallons hydrocarbons as gasoline, was removed <br /> between December 2000 and December 2003 <br /> ' During this period, the petroleum-hydrocarbon concentrations had declined to the point where <br /> utilizing the unit was no longer cost effective in terms of the remediation goals The catalytic SVE <br /> system was replaced on 13 December 2002 with a vacuum blower and 55-gallon moisture collection <br /> canister Operation of a soil vapor extraction(SVE)vacuum blower ceased in January 2004 due to <br /> malfunction of the equipment A sample of the soil vapor from the monitoring events during the last <br /> ' quarter of 2003 was absent of detectable hydrocarbons, therefore SVE was not restarted <br /> Impacted soil was present below the ground water table when remediation began,due to historically <br /> ' lower ground water elevations at the site during which time a portion of the unauthorized <br /> hydrocarbon release occurred The former UST area was impacted by diesel fuel compounds,but is <br /> also impacted by significant concentrations of gasoline fuel compounds <br /> ' The volume of soil addressed by the remediation system was estimated to be 645 cubic meters,based <br /> on the limited lateral extent of the vadose zone contamination and a depth to ground water of <br /> ' 20 feet bsg The generalized mass of vadose-adsorbed TPH-g was approximately 65 2 lbs, or <br /> 29 58 kg, and the generalized mass of adsorbed TPH-d was approximately 77 16 lbs, or 35 kg <br /> ' The total volume of impacted soil addressed by the remediation system was estimated to be <br /> 1,240 cubic meters,from the base of the former UST excavation to the depth of 30 feet bsg The total <br /> mass of adsorbed TPH-g was approximately 123 5 lbs, or 56 8 kg, and the mass of total adsorbed <br /> ' TPH-d was approximately 150 lbs,or 68 2 kg <br /> ' Hydrocarbon-impacted ground water in the former UST area has higher average TPH-g to TPH-d <br /> ratios(0 702- 1 852),indicating a greater contribution to ground water of TPH-g in the former UST <br /> area <br /> ' Advanced GeoEnvironmentni,Inc <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.