Laserfiche WebLink
' .TABLE 4 <br /> SOIL VAPOR EXTRACTION DATA <br /> ' Ripon Farm Services <br /> 22871 South Highway 99, Ripon, California <br /> Vacuum <br /> Hours .Inlet Outlet <br /> Date Time Flow(CFM) inches of ppmv ppmv <br /> ' water <br /> SVE blower installed 07 May 2003 <br /> 05-13-03 9:40 am 144 140 -- 17.6 -- <br /> ' 06-19-03 1:30 pm 1032 132 == 13 <br /> 07-24-03 9:00am 1872 131 39 <br /> 08-14-03 10:30am 2376 -- -- -- '- <br /> ' 09-10-03 12:30 pm 3000 134 30 40 -- <br /> 10-27-03 12:00 pm 4128 128 34 12 -- <br /> 11-19-03 12:00 pm 4656 143 34 -- -- <br /> ' 12-22-03 11:30 am 5424 138 30 5 -- <br /> 10-05-04 11:00 am restart 45 10 -- -- <br /> 1 10-06-04 9:00 am 22 -- -- -- =_ <br /> 10-13-04 1:30 pm 190 48-50 10 6 <br /> 10-27-04 9:00 am 548 68 11 0 -- <br /> 1011-22-04 <br /> 3:00 m 1175 68 10 0 -- <br /> Notes: <br /> cubic feet pre minute:CFM <br /> 1 parts per million volume:ppmv <br /> •hour meter replaced <br /> 1 . <br /> 1 . <br /> 1 <br /> 1 <br /> !1 <br /> 1 Advanced CcoEnvironmental,Inc. <br /> 1 <br />