Laserfiche WebLink
t <br /> Site Background Information: Ripon Farm Service <br /> . Page 3 of 7 <br /> samples at concentrations as high as 3,800 milligrams per kilogram(mg/kg),.Total petroleum <br /> hydrocarbons quantified as diesel(TPH-d)were detected in twelve samples at concentrations <br /> ' as high as 9,000 mg/kg. The maximum concentration of TPH-g was detected in sample B4- <br /> 20; the maximum TPH-d was detected in sample B8-20. <br /> ' TPH-g was detected in ground water samples from MW-1, MW-2 and MW-3 at <br /> concentrations of 1,700 micrograms per liter(µg11), 14,000µg11 and 2,600 gg/l,respectively. <br /> TPH-d was detected in the MW-1, MW-2 and MW-3 samples at concentrations of 2,400 <br /> ' µg11, 9,200 µg11 and 6,900 ggll, respectively. <br /> • With the exception of one sample(B4-20), concentrations of TPH-d exceed concentrations <br /> ' of TPH-g in the soil samples. <br /> In August 1995, five additional soil borings (B9 through B13)were drilled at the site. Two borings <br /> ' were completed as groundwater monitoring wells west and south of the previous three wells(MW-4 <br /> and MW-5).During drilling,ground water was encountered at a depth of approximately 20 feet bsg. <br /> R TPH-g was detected in four soil samples at concentrations as high as 23 mg/kg. TPH-d was <br /> detected in six soil samples at concentrations as high as 1,900 mg/kg. Volatile aromatic <br /> • hydrocarbons(benzene,toluene,ethylbenzene,xylenes: BTEX)were not detected in any of <br /> the soil samples analyzed. <br /> • One grab ground water sample was collected from boring B13 located northeast of the <br /> former USTs. Both TPH-g and TPH-d were detected in the grab water sample at <br /> concentrations of 6,500 µg/l and 450,000 ggll, respectively. BTEX compounds were not <br /> detected in these samples. <br /> 1 <br /> With the exception of sample ASB13/10, the concentrations. of TPH-d significantly exceeded <br /> i concentrations of TPH-g in the soil samples analyzed. Sample ASB13/10 contained 1.0 mg/kg <br /> TPH-g and less than detectable concentrations of TPH-d. <br /> ' In October 1996, three soil probe borings (B14 through B16) were advanced at Jimco Truck Stop, <br /> located immediately north of the site and one boring was advanced on-site (B17•). During drilling, <br /> ground water was encountered at a depth of approximately 20 feet bsg. <br /> ' - were detected in three of eight sail samples analyzed at concentrations <br /> TPH-g and TPHd <br /> ranging from 1.4 mg/kg to 240 mg/kg and from 2.0 mg/kg to 1,700 mg/kg, respectively. <br /> ' Toluene,ethylbenzene and xylenes were detected in the same three samples at concentrations <br /> as high as 1.2 ppm(xylenes,B15-10').Neither benzene nor MTBE were detected in the soil <br /> samples analyzed. <br /> ' Grab ground water samples were collected from three borings (B14, B16 and B17). TPH-g <br /> i <br /> ' Advanced GeoEnvironmental,Inc. <br /> 1 <br />