Laserfiche WebLink
Conditions for N-4428-1-0 (continued) Page 2 of 2 <br /> ' 9 initial compliance with VOC emission rate and control efficiency shall be demonstrated by the results of the <br /> laboratory analysis The results shall be subrrntted to the District within 60 days of the test [District Rule 1081] <br /> . Measurements to determine the influent and the exhaust gas flow rates shall be taken at the initial inspection Flow <br /> ' rate calculations shall be submitted to the District with the laboratory sample analysis results [Distnct Rule 108 1] <br /> I 1 Laboratory samples shall be analyzed for TPH and BTEX [District Rule 1081] <br /> ' 12 Sampling ports adequate for extraction of grab samples, measurement of gas flow rate, and use of an FID, PID or <br /> other District-approved VOC detection device shall be provided for both the influent and effluent gas streams <br /> [District Rule 10811 <br /> ' 13 Laboratory samples shall be taken at the initial inspection, under the supervision of the APCD Inspector Samples <br /> shall be taken from both the influent and the effluent gas stream sampling ports [District Rule 1081] <br /> ' 14 The soil remediation system shall be mairitained in proper operating condition at all times [District NSR Rule] <br /> 15 No air contaminant shall be released into the atmosphere which causes a public nuisance [District Rule 4102] <br /> 16 No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more tbw- three <br /> tminutes in any one hour which is as dark as, or darker than, Ringelrnann I or 20% opacity [District Rule 410 1] <br /> i <br /> 1 <br /> 1 <br /> t <br /> 1 <br /> • <br /> ' N-rta361-a Nw S57v0a 73nAM—f�AST1M0 <br />