Laserfiche WebLink
Conditions for N-4428-1-0 (continued) Page 2 of 2 <br /> 9 Measurements to deterrmne the influent and the exhaust gas flow rates shall be taken at the initial inspection Flow <br /> rate calculations shall be submitted to the District with the laboratory sample analysis results [District Rule 108 1] <br /> Laboratory samples shall be analyzed for TPH and BTEX [District Rule 1081] <br /> 11 Sampling ports adequate for extraction of grab samples, measurement of gas flow rate, and use of an FID, PID or <br /> other District-approved VOC detection device shall be provided for both the influent and effluent gas streams <br /> [District Rule 108 11 <br /> ' 12 Laboratory samples shall be taken at the initial inspection, under the supervision of the APCD Inspector Samples <br /> shall be taken from both the influent and the effluent gas stream sampling ports [District Rule 108 11 <br /> I13 The soil remediation system shall be maintained m proper operating condition at all times [District NSR Rule] <br /> 14 No air contaminant shall be released into the atmosphere which causes a public nuisance [District Rule 41021 <br /> 15 No air contaminant shall be discharged mto the atmosphere for a period or periods aggregating more than three <br /> minutes in any one hour which is as dark as, or darker than, Rmgelmann 1 or 20% opacity [District Rule 4101] <br /> 1 <br /> 1 <br /> 1 <br /> I <br /> 1 <br /> • <br /> gizmo 1105wa-DAVR-M <br />