Laserfiche WebLink
08 Julie 2001 <br /> • AGE-NC Project No 95-0137 <br /> Page 6 of 9 <br /> ' Organic vapor was detected in most soil pilot boring samples at concentrations as high as 477 ppm <br /> at 20 feet bsg PID data is included on the boring logs (Appendix A) <br /> 32 ANALYTICAL RESULTS OF SOIL SAMPLES <br /> ' A total of fourteen soil samples were analyzed for the constituents liste in Section 2 4 <br /> • TPH-g was detected in each of the samples analyzed at concentrations as high as <br /> ' 990 milligrams per kilogram (mg/kg) (VW7-10) TPH-d was also detected in each sample <br /> analyzed at concentrations as high as 1,500 mg/kg (VW6-18) <br /> • BTEX compounds were detected in each sample analyzed Benzene was detected at <br /> concentrations as high as 0 64 mg/kg at a depth of 18 feet bsg(VW3B-18) <br /> ' • The only fuel additive detected was 1,2 DCA, at which was detected at concentrations up to <br /> 20 micrograms per kilogram(,ug/kg) (VW11-15) <br /> ' Analytical results of soil samples are surr manzed on Tables 1 and 2 The laboratory reports (MAT <br /> Lab I D No 36881 to 36894), quality assurance and quality control (QA/QC) report and chain-of- <br /> custody forms are included in Appendix D <br /> 33 SOIL-VAPOR EXTRACTION <br /> The SVE unit operated at varying rates during the observation period Extraction flow rates were <br /> ' initially calculated to range from 40 cfin up to 150 cfm The startup flow rate was low,automatically <br /> diluted with ambient air by the SVE unit, due to the presence of free product or high hydrocarbon <br /> concentrations levels introduced into the SVE system The high concentrations cause the SVE unit <br /> to automatically open the inlet dilution metering valve to stabilize the operating temperature below <br /> 1150 ° F (degrees Fahrenheit) <br /> ' An induced vacuum (negative pressure) of approximately 14 to 30 inches of water was measured in <br /> the piping between the blower and extraction wells An induced vacuum of approximately 0 2 inches <br /> and 0 015 inches was measured at well MW-1 and MW-4, a distance of 10 feet and 45 feet, <br /> ' respectively, from the extraction wells The SVE unit operation was continuous over the quarter <br /> The analytical results are summarized on Table 3 The laboratory reports (MAI Sample Numbers <br /> 55106, 55107, 56077, 56078, 56598, 56599, 57301, 57302,58597, 58598, 60948, 60949, 65177 and <br /> 65178) Quality Assurance and Quality Control (QA/QC) reports and chain-of-custody forms are <br /> included in Appendix E Extracted organic vapor concentrations measured with the OVM were low <br /> compared to the analytical results from the soil-vapor samples The highest concentration of organic <br /> vapor measured with the OVM was 495 ppm <br /> Advanced GeoEnvironmental,Inc <br />