Laserfiche WebLink
a <br /> Appendix A <br /> SAMPLING AND ANALYSIS PROCEDURES <br /> The sampling and analysis procedures for water-quality monitoring programs are <br /> contained in this appendix The procedures provided for consistent and reproducible <br /> sampling methods, proper application of analytical methods, accurate and precise <br /> analytical results, and finally, these procedures provided guidelines so that the overall <br /> objectives of the monitoring program were achieved <br /> The following documents have been used as guidelines for developing these procedures <br /> Procedures Manual for Groundwater Monitoring at Solid Waste Disposal <br /> Facilities, Environmental Protection Agency (EPA) 530/SW-611, August 1977 <br /> Resource Conservation and Recovery Act Groundwater Monitoring Technical <br /> Enforcement Guidance Document, Office of Solid Waste and Emergency <br /> Response 9950 1, September 1986 <br /> Test Methods for Evaluating Solid Waste Physical/Chemical Methods, EPA <br /> SW-846, 3rd edition, November 1986 <br /> Methods for Organic Chemical Analysis of Municipal and Industrial Wastewater, <br /> EPA-600/4-82-057, July 1982 <br /> Methods for Chemical Analysis of Water and Wastes, EPA-60014-79-020, revised <br /> March 1983 <br /> Leaking Underground Fuel Tank Field Manual, California State Water Resources <br /> Control Board, revised October 1989 <br /> Sample Collection <br /> Sample collection procedures include equipment cleaning,water-level and total well-depth <br /> measurements, and well purging and sampling <br /> SAC/pj2\252CN25201000 las 94 pas 3 A-1 Rev 0 07/27/94 <br />