Laserfiche WebLink
} <br /> verify that it contained no air bubbles The sample containers for other parameters were <br /> filled, filtered as required, and capped <br /> When required, dissolved concentrations of metals were determined using appropriate <br /> field filtration techniques When a Teflon bailer was used, the sample was filtered by <br /> emptying the contents of the bailer into a pressure transfer vessel A disposable <br /> 0 45-micron acrylic copolymer filter was threaded onto the transfer vessel at the discharge <br /> point, and the vessel was sealed Pressure was applied to the vessel with a hand pump and <br /> the filtrate directed into the appropriate containers Each filter was used once and <br /> discarded <br /> When a bladder pump was used to collect samples for dissolved constituents, filtering was <br /> performed by attaching a disposable 0 45-micron acrylic copolymer filter directly to the <br /> pump effluent line with a pressure fitting As the pump cycled, the effluent was pressured <br /> through the filter and directed into the appropriate containers Each filter was used once <br /> and discarded <br /> Sample Preservation and Handling <br /> The following section specifies sample containers, preservation methods, and sample <br /> handling procedures <br /> Sample Containers and Preservation <br /> Sample containers vary with each type of analytical parameter Container types and <br /> materials were selected to be nonreactive with the particular analytical parameter tested <br /> Sample Handling <br /> Sample containers were labeled immediately following collection Samples were kept cool <br /> with cold packs until received by the laboratory Cold packs were replaced each day to <br /> maintain refrigeration At the time of sampling, each sample was logged on a <br /> Chain-of-Custody Record that accompanied the sample to the laboratory <br /> Samples were transferred from the site to a state-certified laboratory by the sampling <br /> team Sample shipment from EMCON Associates (EMCON) to laboratories performing <br /> the selected analyses routinely occurred within 24 hours of sample receipt The laboratory <br /> manager checked the holding times for requested analyses so that they were not exceeded <br /> Sample Documentation <br /> The following procedures were used during sampling and analysis to provide <br /> chain-of-custody control during sample handling from collection through storage Sample <br /> documentation included the use of the following <br /> 0 Field logbook to document sampling activities in the field <br /> SAC/pj2\252(1\25201000 lac 94 pac 9 A-4 Rev 0 07/27/94 <br />