Laserfiche WebLink
6' - 0" MAX, TYP. <br /> I I GC TO PROVIDE 2" MIN <br /> PLASTIC GROMMET <br /> O <br /> WOOD SCREWS, <br /> TYP. O <br /> A` 1/2" GYP BD <br /> PENDANT LIGHT FIXTURE ©2011 STARBUCKS COFFEE <br /> SUPPORT OR SIMILAR <br /> SUPPORT <br /> STARBUCKS COFFEE <br /> (E) ROOF (E) ROOF <br /> FRAMING FRAMING ` COMPANY <br /> CJ PENDANT LIGHT FIXTURE OR 2401 UTAH AVENUE SOUTH <br /> 4" X 18 GA. STEEL BRACING �� SIMILAR PENETRATION <br /> AT 48" O.C. (PROVIDE CONT. + SEATTLE, WASHINGTON 98134 <br /> BRIDGING W/2-#10 SCREW TO (206) 318-1575 <br /> EA. BRACE WHEN BRACE IS <br /> MORE THAN 12'-0" IN LENGTH). THESE DRAWINGS AND SPECIFICATIONS ARE <br /> CONFIDENTIAL AND SHALL REMAIN THE SOLE <br /> PROPERTY OF STARBUCKS CORPORATION,WHICH IS <br /> THE OWNER OF THE COPYRIGHT IN THIS WORK. <br /> PLASTIC GROMMET <br /> @ THEY SHALL NOT BE REPRODUCED (IN WHOLE OR IN <br /> 4" X 18 GA. STEEL PART), SHARED WITH THIRD PARTIES OR USED IN AN <br /> 4" X 18 GA. STEEL BRACING STUDS 16" OC MANNER ON OTHER PROJECTS OR EXTENSIONS TO <br /> AT 48" O.C. (PROVIDE CONT. scale: 1/4" = 1' O" THIS PROJECT WITHOUT THE PRIOR WRITTEN <br /> BRIDGING W/2410 SCREW TO W/4#10 SCREWSTO (E) JOISTS. � 5/8" GYP. BD, TYP CONSENT OF STARBUCKS CORPORATION. THESE <br /> }, EA. BRACE WHEN BRACE IS DRAWINGS AND SPECIFICATIONS ARE INTENDED TO <br /> > MORE THAN 12'-0" IN LENGTH). TWO (2) NO. 12 GAUGE WIRES MUST BE LATERAL FORCE BRACING MEMBERS MUST BE EXPRESS DESIGN INTENT FOR A PROTOTYPICAL <br /> SECURED FROM LIGHT & MECHANICAL SPACED A MIN OF 6" FROM ALL HORIZONTAL STARBUCKS STORE (WHICH IS SUBJECT TO CHANGE <br /> - PIPING OR DUCT WORK THAT IS NOT PROVIDED AT ANYTIME AND DO NOT REFLECT ACTUAL SITE <br /> FIXTURES AT OPPOSING CORNERS � - ---- ) <br /> I - ALONG THE FIXTURE'S DIAGONAL. <br /> - W/BRACING RESTRAINTS FOR HORIZ FORCES. CONDITIONS. NEITHER PARTY SHALL HAVE ANY <br /> 0 <br /> O WIRES MAY BE SLACK. BRACING WIRES MUST BE ATTACHED TO THE OBLIGATION NOR LIABILITY TO THE OTHER (EXCEPT <br /> Y GRID &TO THE STRUCTURE IN SUCH A MANNER STATED ABOVE) UNTIL A WRITTEN AGREEMENT IS <br /> U NOTE: --------- THAT THEY CAN SUPPORT A DESIGN LOAD OF FULLY EXECUTED BY BOTH PARTIES. <br /> FOUR NO. 12 GAUGE WIRES MUST BE NOT LESS THAN 200 POUNDS OR THE ACTUAL <br /> SECURED TO THE MAIN RUNNER WITHIN 2" LOAD, WHICHEVER IS GREATER, WITH A SAFETY <br /> U) 4" X 18 GA. STEEL BRACING OF THE CROSS RUNNER INTERSECTION FACTOR OF 2. ARCHITECT OF RECORD <br /> O <br /> AT 48" O.C. (PROVIDE CONT. AND SPLAYED 90 DEGREES FROM EACH <br /> 4" X 18 GA LEDGER + 4" X 18 GA BRIDGING W/2 #10 SCREW TO + 4" X 18 GA OTHER AT AN ANGLE NOT EXCEEDING 45 <br /> W/ (2) #10 X 3" LONG + BLOCKING, TYP EA. BRACE WHEN BRACE IS + BLOCKING, TYP DEGREES FROM THE PLANE OF THE LIGHT FIXTURE > o • <br /> WOOD SCREWS AT + MORE THAN 12'-0" IN LENGTH). + CEILING. (MAY BE SLACK) (LESS THAN 56 LBS) <br /> EACH (E) STUD, TYP. C <br /> + e NO. 12 GAUGE _ <br /> NI WIRES WITHIN 3" OF ----------- -� 3" MAX <br /> o . a ALL 4CORNERS. mcg a r c h i t e c u r <br /> - <br /> - PR VIDE MINIMUM F 2 REW AT <br /> M 111 Pacifica, Suite 280, Irvin, CA 92618 <br /> r OPPOSITE CORNERS OF SUPPORT P:949.553.1117 F:949.474.7056 <br /> X WIRES, OR SCREW ON T-BAR NOTE: <br /> m #10 SMS AT EACH (4) #10 SMS. 4" X 18 GA. STEEL STUDS AT 16" PROVIDE EARTHQUAKE <br /> O.C. WITH 4 -#10 SCREWS, TYP SAFETY CLIPS AT SIDES OR ENDS. CLIPS &WIRES AS REQ'D. ARCHITECT STAMP <br /> SIDE AND EACH STUD. TYP. <br /> I SEE 1/1103 FOR <br /> M 5/8" GYP. BD, TYP HEIGHT OF SOFFIT G SPED A <br /> SUSPENDED GE WIN i <br /> CEILING GRID <br /> -41839 <br /> 19 SOFFIT DETAIL7 - <br /> CEILING LIGHT DETAIL <br /> �, scale: 1 1/2" = V-0" Scare: 3/8" = V-0" F CAL <br /> T <br /> b <br /> 0 VERTICAL STRUT @ 12" O.C. MAX. EACH COMPRESSION STRUT GUIDELINES <br /> M WAY WITH FIRST POINT TO BE WITHIN 6" NOTE: <br /> FROM EACH WALL FASTENED TO MAIN 8 GA HANGER WIRE TO VERIFY ASSEMBLY WITH TRUSS COMPRESSION STRUT SIZE MAXIMUM LENGTH <br /> U RUNNER & STRUCTURE ABOVE @ 4'-0" MFG WHERE 1 HR ASSEMBLY IS <br /> Q STRUCTURE ABOVE PER ASCE-7 13.5.6.2.2 A OC NW/4 WIRES SPLAYED 90 REQ'D 3/4" DIAMETER STRUT 12'-0" <br /> N deg IN 4 DIRECTIONS (450 <br /> o XQ MAX FROM CEILING PLANE) 1" DIAMETER STRUT 18'-0" <br /> 0 12 GA. VERTICAL SINGLE 2 1/2"x 20 GAUGE METAL STUD (I MIN. = 0.18") 11'-6" <br /> 75 EACH <br /> WIRE AT 4'-0" 900 900 TYPE "S" SCREW <br /> EACH — t f 2'-0" <br /> Q WAY WITH MIN. 3 TIGHT MAX @ 8" OC BACK-TO-BACK 2 1/2"x 20 GAUGE METAL STUD SCREWED 15'-0" <br /> TOGETHER @ 24" O.C. O <br /> U TURNS 1-1/2"AT BOTH HEAVY DUTY T-BAR SYSTEM <br /> 20 GAUGE r <br /> ENDS OF WIRE (TYP.) U CHANNEL @ <br /> O O � ° ° 12 GA WIRE HANGER @ 48" O.C. r^ CV <br /> } _ PER ASTM AC 635 & ASTM AC ;, V J <br /> U 24"OC LO <br /> 636. SEC 1613.1 CBC. EA. WAY. FIRST POINT TO BE 8" ^ <br /> O CROSS RUNNERS N FROM WALL. W O7 <br /> �I T VERTICAL COMPRESSION <br /> ANDBRAC NG W R S@ 2'-OSTRUT <br /> O.C. Q <br /> ° MAX. EACH WAY. FIRST POINT TO ,�( J <br /> �j Cn I Q fi fi ' ° BE WITHIN 6'-0" FROM EACH WALL. ` 6 WL z <br /> c � g a ° A FASTENER TO MAIN RUNNER & <br /> 06 ° v f� 20 GAUGE WIRE S°Qij STRUCTURE ABOVE WITH 1/4" 2i = 0 � O <br /> X 2" � ° ��° q� MACHINE BOLTS. SEE NOTE 4. z Q LIJ <br /> U ( , <br /> Cz <br /> MAIN RUNNERS 1-1/2" 20 GAUGE P� v <br /> �` 2" MAX. FROM BRACING <br /> COLD ROLLED U = U (� <br /> WIRES TO CROSS TEESW W 0 <br /> O <br /> NI X STEEL @ 48" OC 12 GA. BRACING WIRE WITH MIN. 8" MAX <br /> Q BRACING WIRES TO BE ATTACHED Q Q <br /> It 0 0 <br /> co 4 TIGHT TURNS IN 1-1/2"AT 6'-0" 12'-0"OC @ MAX OF 45 DEGREES. MIN OF 4 CY IY <br /> BOTH ENDS OF WIRE (TYP.) AT eo / GYP, <br /> FIRE RATED �\ LO U) <br /> r GYP, ALL EDGES TIGHT TURNS IN 1-1/2" @BOTH <br /> X EACH VERTICAL STRUT <br /> m MAX 75 AT TWO ADJACENT SUPPORTED v o 0 x ENDS OF ALL BRACING WIRE TYP. <br /> NOTES: WALLS. SEE NOTE 2 5 GYPSUM BOARD D ETA I L X d STORE #: 13402 <br /> ' " <br /> MAIN RUNNER @ 4-0O.C. <br /> N REFLECTED CEILING PLAN scale: 1/4" = V-0° PROJECT #: 39714-051 <br /> 1. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE <br /> o INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SHIM AS NEEDED LARR#25764 CASEWORK CONCEPT: CORE <br /> U) ASTM C 635 AND ASTM C 636. <br /> ICC ER#1222 ISSUE DATE: <br /> Y LINE OF WALL CROSS TEE @ 2'-0"O.C. PROGRAM MANAGER: M. DREBIKA <br /> () 2. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2"OF OR V-0" O.C. AS SHOWN <br /> Z) THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM 6'-0" MAX. 6'-0" MAX. STORE DESIGNER: S. BELVINS <br /> m ° 12' - 0" MAX. 12' - 0" MAX. ATTACHMENT CLIP NOTES: <br /> 00 EACH OTHER AT AN ANGLE NOT EXCEEDING 45 FROM THE LEEDOAP: N/A <br /> PLANEOF THE CEILING 1. ALL 24"X48" CEILING LIGHT FIXTURES & 24"X24" HVAC AIR REGISTERS SHALL BE <br /> < 8" MAX 8" MAX CHECKED BY: <br /> MAIN T GRID (USG SUPPORTED BY A MINIMUM OF (2) HANGERS @ OPPOSITE CORNERS. CEILING SYSTEM SHALL <br /> U) 3. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF NOT SUPPORT OTHER ITEMS. MCG PROJECT#: 19233 <br /> o THE CEILING GRID SHALL BE ATTACHED TO A MINIMUM 2" WIDE DX26, MCG PROJ. MANAGER: C.LEE <br /> C) BLACK COLOR)w THE OTHER END IN EACH HORIZONTAL w <br /> CLOSURE ANGLE. 2. ALL INTERIOR WALL& CEILING FINISHES SHALL BE INSTALLED TO CLASS III FLAME SPREAD. <br /> i MCG PROJ. SPECIALIST: SPARK <br /> j DIRECTION SHALL HAVE 0.75" CLEARANCE FROM THE WALL AND U) ~O s° NO. 12 GA MIN <br /> O SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE z VERTICAL HANGER 3. 45 DEGREE BRACE WIRES & COMPRESSION STUDS ARE TO BE PROVIDED ONLY IF <br /> o ANGLE. A WIRE, SEE NOTE 3 REQUIRED BY LOCAL BUILDING DEPARTMENT. Revision Schedule <br /> rn 4. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND = > ', 4. COMPRESSION STRUTS : STEEL SECTION ATTACH TO MAIN RUNNERS WITH 1/4" MACHINE Rev Date By Description <br /> r THE CEILING EXCEEDS 4", THE SPACING OF THE VERTICAL 0 ACOUSTICAL TILE U BOLT AND TO STRUCTURE WITH 3/16" DIAMETER POWER DRIVEN STUD. COMPRESSION STRUT <br /> N HANGERS SHALL NOT EXCEED 2'O.C. ALONG THE ENTIRE MEANS CEILING ON SUSPENDED .75"AT TWO SHALL NOT REPLACE HANGER WIRE. <br /> OF EGRESS SERVICING THE OCCUPANT LOAD OF 30 OR MORE, GRID SYSTEM ADJACENT WALLS <br /> AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. = SEE NOTE 2 5. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER <br /> Ln <br /> — COMPRESSION STRUT CEILING PANEL INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING <br /> 5. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATER z_ 45 DEGREES FROM THE PLANE OF THE CEILING. <br /> 75 DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, <br /> Q SHOW A 2" OVERSIZED RING, SLEEVE OR ADAPTER THROUGH \ — I MIN WALL ANGLENSTALLED 1/4" BELOW MAIN <br /> ( 6. CLOSURE ANGLE SHALL BE A MINIMUM OF 2". SHEET TITLE: <br /> co THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST (I <br /> N 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY A SWING GRID) 7. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN CEILING DETAILS <br /> U-) JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN SECTION THROUGH ROOM PROVIDE COMPLETE 2" IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE <br /> ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT INSTALLATION AS RECOMMENDED ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION <br /> rn THE TOP OF THE SPRINKLER HEAD EXTENSION. PER ASCE 7-05, BY MANUFACTURER AND CODES SHALL HAVE A 0.75" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SCALE:AS SHOWN <br /> CD SEC 13.5.6.2.2. <br /> SLIDE ON A CLOSURE ANGLE. <br /> N SHEET NUMBER: <br /> N *TS -le:TYPICAL SUSPENDED CEILING VERTICAL & LATERAL SUPPORT T-BAR TO WALL DETAIL 1 T-BAR CEILING DETAIL1505 <br /> 1/8"= V-0" scale: 6" = 1'-0" scale: 1/4" = V-0" <br />