My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2020 12:14:14 PM
Creation date
5/1/2020 9:04:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page -5 of <br /> 7. Ui-,.SER-DISPENSER CONTAINMENT(Ui,-)TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional-Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> UDC Manufacturer: <br /> UDC Material: f;"T e <br /> UDC Depth: <br /> Height from UDC Bottom to Topp , <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to r2"Above <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior totestin : <br /> Portion of UDC Tested' Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> tration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> Is system programmed for fail- ❑Yes❑ No NA® ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® <br /> safe shutdown?' <br /> Was fail-safe verified to be ❑Yes❑ No NA® ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® <br /> operational?* <br /> Wait time between applying 'JE <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: /Z i 2 3 /Z : Z y !2 tj /2=I(z < <// /:39 /: /: z 2 <br /> Initial Reading(Rj): lyra ` ° P` i /,fl '/3 <br /> Test End Time: /2 1 9 /Z'5-7 /' ) 'S11 /•'35" .'3 7 <br /> Final Reading(RF): /D t 9 a /, 7W 17 1XV /b, .7 /Z- A If I Z o,9P f 6 <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RO: ,'eliz 6140'1 q •e�/0w07Z o.-p2 0.--00-'4 eloeeS3 <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Was sensor removed for testing? ❑Yes❑ No NAE] ❑Yes❑ No NAE] ❑ Yes❑ No NAE] ❑Yes❑ No NA❑ <br /> Was sensor properly replaced and ❑Yes❑ No NA❑ ❑Yes❑ No NA❑ ❑ Yes❑ No NAE) ❑Yes❑ No NAL] <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> Arco # 6020 <br /> 1711 E. YOsemite Ave. <br /> Manteca, CA. 95336 <br /> N05116— SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.