My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1711
>
2300 - Underground Storage Tank Program
>
PR0231455
>
COMPLIANCE INFO_2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2020 12:14:14 PM
Creation date
5/1/2020 9:04:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0231455
PE
2361
FACILITY_ID
FA0003612
FACILITY_NAME
Yosemite Avenue Arco AmPm
STREET_NUMBER
1711
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1711 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> f <br /> 1 <br /> I Piping Leak Detection Monitoring Equipment <br /> ' tblonitorin Mev'iod I Manufacturer Model Monitoring Frequency <br /> ®Sump leak sensors connected to <br /> continuous monitoring system ( Veeder Root 794380-323 <br /> 1 Specify type: <br /> Continuous � <br /> ❑ Discriminating <br /> i <br /> ®Non-discriminating 1 <br /> M Mechanical line leak detectors with RED JACKET XLD(89&91 tanks) I <br /> programmed leak threshold of three Every pumping cycle <br /> gallons per hour FE PETRO MLD 87 tank <br /> Electronic line leak detectors with --- t <br /> programmed teak Threshold of: Every pumping cycle I <br /> ❑0.1 gph 00.2 gph 03 gph I <br /> (] Line integrity testing by: <br /> ❑ Electronic tine leak detector is <br /> equipped to conduct line tightness ❑Annually <br /> itesting <br /> El Third party testing ❑Other. <br /> 0 Not required <br /> ❑Other(Specify): <br /> 4. Dispenser(Leak Detection Monitoring Equipment <br /> Monitoring Method Manufacturer Model �— Monitoring Frequency <br /> ❑ Mechanical float in dispenser <br /> rnntainmgnt Continuous <br /> ® Electronic leak sensor in dispenser — -- <br /> containment: teeder Root 794380-323 <br /> ❑Discriminating Continuous <br /> ® Non-discriminating <br /> ElVisual inspection T— ❑ Daily <br /> —__—__-- ❑Other: <br /> ❑No under-dispenser containment — —El Other Other(specify): - — — <br /> S. Positive Shutdown Capabilities <br /> L System does not have positive shutdown capabifities -- <br /> ❑Individual dispenser shutdown will occur whenever release is sensed in under-dispenser containment <br /> ®Automatic pump shut off will occur whenever: --- <br /> ® Release is sensed in turbine sump <br /> (] Release is sensed in primary piping <br /> ®Release is sensed at dispenser <br /> ®Monitoring system is disconnected or fails in any way(fail safe) <br /> ❑Other(specify): <br /> 6.Secondary Containment Testing <br /> ❑Secondary containment is not tested _ <br /> In the State of California,secondary containment systems installed on or after January 1,2001,shall be tested upon installation, <br /> Lsix months after installation,and every 36 months thereafter- Secondary containment systems installed prior to January 1,2001, <br /> shall be tested by January 1,2003,and every 36 months thereafter. <br /> 7. Annual Equipment Certficationfresting <br /> ®Annually <br /> 11 Other(specify): <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.