Quarterly Monitoring Report Wober 2000 <br /> Ganepa s Car Wash(Pal k Street) <br /> January 25 2001 <br /> Page 6 <br /> 6. RECOMMENDATIONS <br /> Condor recommends that additional investigation be conducted to further characterize the extent of <br /> contamination at the site, including the installation and sampling of additional monitor wells The <br /> existing monitor wells at the site are screened well below the cur rent groundwater table and do not <br /> provide sufficient rntormation pertaining to the vadose zone/groundwater interface These wells should <br /> be augmented with well screens that intercept the first groundwater A work plan desct rbrrrg the <br /> recommended installation of four additional monitor wells (MW-8 through MW-11) was prepared and <br /> submitted to the PHS/EHD to November 1998 rhe work plan is currently pending approval by the <br /> PHS/EHD <br /> Condor recommends the following <br />' 0 PHS/EHD response to and/or approval of the submitted work plan <br /> 0 The installation of new monitor wells that are properly screened at the first groundwater <br /> • A sensitive receptor survey within a 2,000-foot radius of the site <br /> If you need additional information or have any questions, please contact us at(209) 234-0518 <br /> Respectfully submitted, <br /> CONDOR EARTH TECHNOLOGIES, INC <br /> Marrkka L Hughes No. 6430 onald F Kresse <br />' Staff Geologist N alifornraRegistered <br /> ,A Q eoiogrst#6130 <br /> OF CA��Fp� <br /> V 12038 C 111CP-1 P Ui \QIL U ICI ly Vlnnaouuy Repoi ts120U I i mu1:ylQ1\1 Rt D I dog <br /> ti CONDOR ` <br />