Laserfiche WebLink
I <br />' 25 February 2005 <br /> • AGE-NC Project No 96-0229 <br />' Page 4 of 6 <br />' (Figure 4),off-site towards the north and northeast(wells MW-6 through MW-12),net ground water <br /> flow was oriented more towards the north-northeast at an average hydraulic gradient of 0 005 ft/ft <br />' 3 12 Second Water Zone <br />' Ground water elevation data collected in the Second Water Zone (70 to 95 feet bsg) at the site and <br /> off-site (wells MW-5 and MW-6 through MW-12) inferred a net ground water flow direction <br /> towards the east at hydraulic gradients between 0 007 ft/ft and 0 008 ft/ft (Figure 5) <br /> 3 2 LABORATORY RESULTS OF GROUND WATER SAMPLES <br />' A total of forty-one ground water samples were submitted to Ca Tech Environmental Laboratories <br /> (CTEL), a DHS-certified laboratory in Paramount, California <br /> iTPH-g was detected in ground water samples collected from wells MW-1 through MW-4, MW-6 <br /> • and MW-9 at concentrations as high as 53,000 micrograms per liter (µg/1) in well MW-2 <br /> i BTEX compounds were detected In samples MW-1 through MW-4 MW-6 and MW-9 at <br /> p P g <br /> i concentrations as high as 8,800 µg/l (xylene, MW-2), the highest benzene concentration was <br /> detected In sample MW-1 at a concentration of 3,100 µg/l <br /> i The fuel additive MTBE was detected by EPA Method 8260 in samples MW-1 through MW-4, <br /> MW-6, MW-9, MW-16 (B-C), and MW-19A at concentrations as high as 600 µg/1 (MW-9), in <br /> addition, 1,2-DCA was detected in the ground water samples collected from wells MW-1 and MW-2 <br /> i at concentrations of 170 µg11 and 12 µg/1,respectively, and DIPE was detected in one ground water <br /> sample collected from well MW-1 at a concentration of I 1 µg11 <br /> i No other constituents of concern were detected above laboratory reporting limits In the analyzed <br /> samples Previous and current analytical results of ground water monitoring well samples are <br /> summarized In Table 3 The laboratory reports (CTEL Project Number CT214-0410004), quality <br /> assurance/quality control(QA/QC)reports and chain of custody forms are presented in Appendix B <br /> GeoTracker confirmation pages of the submitted laboratory electronic deliverable format(LOP)files <br /> are included in Appendix C <br /> i <br /> 4.0. SUMMARY AND CONCLUSIONS <br /> The implications from the findings of the September 2004 round water monitoring event are <br /> • P g p g <br /> iAdvanced CeoEn"ronmental,Inc <br /> i <br />